FIME Smoke Extractor for Saunier Duval Renova Micra 24 SE Boiler - Ref. ECRM23SE
RefurbishedRenovaExtractor fansFIME

FIME Smoke Extractor for Saunier Duval Renova Micra 24 SE Boiler - Ref. ECRM23SE

Stock · 5 units

If your boiler does not ignite or gets blocked due to a flue gas evacuation fault, you may need the FIME flue extractor, reference 0020076139. This fan is responsible for evacuating combustion gases and creating the necessary draft for the boiler to start. When it fails, the fault code F.32: Fault: fan may appear. It is compatible with models from the EURA, HABITAT, LASER, RENOVA, and SUPERMICRA ranges, among others. It is recommended to replace it when you notice ignition problems or blockage due to flue gas evacuation.

VAT included

Compatibility

Renova boilers compatible with reference 03500999

Extractor with reference 03500999. Five confirmed compatibilities: 23 SE and 23 SE.

Proven compatibility

Boiler modelFamilyVerification
Renova 23 SEEURAContrasted
Renova 23 SEHABITATContrasted
Renova 221 SELASERContrasted
Renova MICRA 24 SERENOVAContrasted
Renova 24 SESUPERMICRAContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number 03500999 is the one for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 03500999. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor 03500999 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, stops after a few seconds, and does not produce a flame.

    Cause: The pressure switch does not close the contact because the extractor does not reach the minimum safety depression.

    Check that the silicone tubes of the pressure switch are not bent, loose, or blocked before replacing the fan.

  • 02

    The extractor makes a metallic noise or a high-pitched beep when starting up.

    Cause: The motor bearing is worn out and the shaft rubs against the casing while rotating.

    Turn the impeller by hand with the boiler off; if you notice friction or a hard spot, confirm the wear of the bearing.

  • 03

    The boiler locks itself during operation with a fault warning for flue gas extraction or smoke.

    Cause: The extractor loses flow in hot conditions because the motor overheats or the impeller is dirty, and it fails to maintain the required pressure.

    Let the boiler cool down and repeat a start cycle to see if the fault occurs at the same operating time; this points to overheating of the motor.

  • 04

    The extractor spins very slowly or intermittently, almost without power.

    Cause: The motor is losing winding or the impeller is dragging due to accumulated dirt, and it does not reach the speed required by the boiler.

    Listen for whether the extractor starts strong and then decreases, as opposed to a constant buzzing without spinning: these are different faults.

Fault codes for Renova that this spare part resolves.

CodeFaultDiagnosis and solution
F.32Fault: fan.The flue fan (Ref. 03500999) is blocked, not spinning at the expected RPM, or not sending the tachometer signal to the PCB; there may also be a disconnected connector/harness or an obstruction in the air/flue. Check power supply to the fan, tachometer signal, free rotation, and absence of obstructions in the intake/exhaust.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Renova extractor data sheet 03500999

Catalogue reference
03500999
Brand
Renova
Type of part
Extractor fans
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
FIME
Before purchasing
  • The manufacturer listed on the part is FIME, not Saunier Duval: it is the actual manufacturer of the component, not of the boiler.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the extractor 03500999

Does this extractor FIME work for a Saunier Duval Renova Micra 24 SE?
Yes, the Renova Micra 24 SE is on the list of compatible boilers for this part.
Who manufactures the extractor for the Saunier Duval Eura 23 SE?
It is manufactured by FIME, as stated on the motor label.
What fault indicates that the extractor needs to be replaced in a Saunier Duval Habitat 23 SE?
Ignition failure, excessive noise in the fan, or boiler blockage due to extraction fault.

Spare parts related to Renova EURA

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model