
Saunier Duval ThemaClassic F 25 E Extractor Fime GR01040B Ref. S1008800
The Saunier Duval ThemaClassic F 25 E Fime GR01040B is a flue fan responsible for expelling combustion gases and creating the necessary draft for the boiler to start. When it fails, the boiler may not ignite or may lock out due to a fault in the flue gas evacuation, displaying fault code F3. This fan is compatible with models such as ThemaClassic F 24 E and ThemaClassic F 25 E, among others in the ThemaClassic and Thematek ranges. It should be replaced when issues are detected in ignition or gas evacuation.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1008800
Extractor with reference S1008800. Three confirmed compatibilities: ThemaClassic F 24 E and ThemaClassic F 25 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic F 24 E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F 25 E | ThemaClassic | Contrasted |
| Saunier Duval Thematek F 24 E | Thematek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1008800 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1008800. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor S1008800 resolves.
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler won't start, or it tries to but stops immediately.
Cause: The extractor does not spin fast enough for the air pressure switch to close the contact and allow the control board to enable ignition.
Before changing it, check if the fan starts spinning immediately when power is supplied to the boiler or if it takes time or remains stationary.
- 02
A buzzing or loud continuous noise is coming from the extractor.
Cause: With use, the motor bearing wears out and the rotor starts to rub while rotating.
Gently touch the casing of the extractor while the boiler is running: if the noise is more noticeable there than in the outlet pipe, it points to the motor.
- 03
The boiler is locking out with a fault of lack of draft or flue gas evacuation.
Cause: If the extractor does not generate sufficient depression, the pressure switch does not detect flow and the control board shuts off for safety.
Check that the exhaust duct to the outside is not obstructed, crushed, or blocked, and that the silicone tubes to the pressure switch are properly connected before declaring the fan faulty.
- 04
The extractor is spinning slowly, jerking, or not moving at all.
Cause: It is usually the motor winding or the bearings that no longer allow reaching the rotation speed required by the boiler.
With the boiler unplugged, turn the turbine by hand: if you feel friction or it doesn't turn freely, the motor needs to be replaced.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F3 | The boiler stops due to obstruction in the flue gas outlet. | The boiler shuts down automatically due to a blockage in the flue gas outlet. This can happen if the extractor is not functioning properly. To determine if the problem is with the extractor, check for any strange noises or if the fan is not running. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval S1008800 Extractor Datasheet
- Catalogue reference
- S1008800
- Brand
- Saunier Duval
- Type of part
- Extractor fans
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- FIME
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Themaclassic F 25 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.












