Fime Saunier Duval ThemaClassic F24 E Extractor Ref. S1008800
RefurbishedSaunier DuvalExtractorsFIME

Fime Saunier Duval ThemaClassic F24 E Extractor Ref. S1008800

Stock · 1 unit

If your boiler does not ignite or gets blocked due to a flue gas evacuation fault, you may need the Fime Extractor Saunier Duval ThemaClassic F24 E Ref. S1008800. This flue fan is responsible for evacuating combustion gases and creating the necessary draft for the boiler to start. When it fails, it can generate the fault code F3: Flue gas obstruction. It is compatible with models such as ThemaClassic F 24 E, ThemaClassic F 25 E, and others from the ThemaClassic and Thematek ranges. It should be replaced when issues are detected in the flue gas evacuation or the operation of the fan.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1008800

Extractor with reference S1008800. Three confirmed compatibilities: ThemaClassic F 24 E and ThemaClassic F 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic F 24 EThemaClassicContrasted
Saunier Duval ThemaClassic F 25 EThemaClassicContrasted
Saunier Duval Thematek F 24 EThematekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1008800 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1008800. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor S1008800 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, goes through the startup cycle, and locks out showing a flue gas fault.

    Cause: The extractor does not spin enough for the air pressure switch to close the contact, and the control board cuts off the gas for safety.

    Check that the silicone tubes of the pressure switch are properly connected and not pinched before assuming that the fault is with the extractor.

  • 02

    A rubbing, squeaking, or loud vibration noise is heard right when starting the boiler.

    Cause: The motor bearing or the impeller is worn and rubs against the casing while rotating.

    With the boiler turned off and unplugged, turn the turbine by hand: if you feel friction or it stops abruptly, the wear is confirmed.

  • 03

    The extractor does not start at all when the boiler requests heat.

    Cause: The motor has lost electrical continuity or has seized after a long period of inactivity.

    Check if this occurs right after a power cut or a long shutdown; sometimes a new attempt to ignite releases it, although if it happens again, it needs to be replaced.

  • 04

    The boiler stops by itself during operation, not just when starting.

    Cause: The extractor loses revolutions while running and stops generating the minimum pressure required for safe exhaust.

    Before replacing the part, check that the flue gas outlet terminal outside is not blocked by ice, a nest, or dirt: it gives the same symptom.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F3Obstruction in flue gas outletThe boiler stops automatically. It is important to check for partial or total obstructions in the flue gas outlet. If the fault code F3 appears, check the condition of the fan and ensure there are no blockages.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval S1008800 Extractor Datasheet

Catalogue reference
S1008800
Brand
Saunier Duval
Type of part
Extractors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Fime
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the extractor S1008800

Is this Fime extractor original from Saunier Duval or a third-party component?
The manufacturer identified on the part is Fime, not Saunier Duval; it is used as a spare part in several boilers of that brand.
Is this Fime extractor suitable for my Saunier Duval ThemaClassic F25 E?
Yes, it is among the indicated compatible models: ThemaClassic F 24 E and ThemaClassic F 25 E.
Which models are compatible with the extractor Fime Saunier Duval ThemaClassic F24 E Ref. S1008800?
The compatible models are: ThemaClassic F 24 E, ThemaClassic F 25 E, and Thematek F 24 E.
What fault code is documented for this extractor?
The documented fault code for this extractor is F3.
What is the reference for this Fime extractor?
The reference for this extractor is ECTC24E.
Can I use this extractor on boilers from other brands?
This extractor is specifically designed for the models in the mentioned ranges and is not compatible with boilers from other brands.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fime Saunier Duval ThemaClassic F24 E Extractor Ref. S1008800