Saunier Duval Master Twin L85E Extractor Ref. 05603600

Saunier Duval Master Twin L85E Extractor Ref. 05603600

75 €VAT includedIn stock · 5 units

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with Master Twin L85E, Twin F28E, Thelia 30E (ref. 05603600). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
05603600
Brand
Saunier Duval
Type of part
Extractors
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 05603600) equips these models. Verified compatibility; check the reference before purchasing.

Master Twin

  • Master Twin L85E

Twin

  • Twin F28E

Thelia

  • Thelia 30E
  • Thelia Twin 28E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.32Fault: fanThe extractor (fan) gets blocked/faulty or its tachometer/Hall signal is invalid, causing the rpm to go out of tolerance and the boiler goes into lockout; check the motor power supply and connectors, and verify rotation/consumption or rpm from diagnostics.
F.33Air pressure switch faultThe extractor does not generate the required depression/flow and the pressure switch does not close, causing the fault; check the fan start-up and flow, measure the pressure switch closure at the start, and inspect the ducts/Venturi.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 05603600 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Master Twin L85E

Scroll to the top