Vaillant Ecotec Plus VMW ES 296 3 5 Extractor Ref. 193593
Extractor: reconditioned spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with VMW 236/3-5, VMW 236/3-5 R3, VMW 236/3-5 R5 (ref. 193593). Includes a one-year warranty. Delivery time and cost are shown at checkout for the destination country.
VAT included
Consult via WhatsAppVaillant boilers compatible with reference 193593
Extractor with reference 193593. 11 confirmed compatibilities: VMW 236/3-5 and VMW 236/3-5 R3.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMW 236/3-5 | ecoTEC plus VMW (combi condensing) | Contrasted |
| Vaillant VMW 236/3-5 R3 | ecoTEC plus VMW (combi condensing) | Contrasted |
| Vaillant VMW 236/3-5 R5 | ecoTEC plus VMW (combi condensing) | Contrasted |
| Vaillant VMW 296/3-5 | ecoTEC plus VMW (combi condensing) | Contrasted |
| Vaillant VMW 346/3-5 | ecoTEC plus VMW (combi condensing) | Contrasted |
| Vaillant VMW 226/3-3 | ecoTEC plus VMW (combi condensing) | Contrasted |
| Vaillant VM 246/3-5 | ecoTEC plus VM (heating only) | Contrasted |
| Vaillant VM 246/5-5 | ecoTEC plus VM (heating only) | Contrasted |
| Vaillant VM 376/3-5 | ecoTEC plus VM (heating only) | Contrasted |
| Vaillant ecoTEC pro 24 | ecoTEC pro | Contrasted |
| Vaillant ecoTEC pro 28 | ecoTEC pro | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 193593 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 193593. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor 193593 resolves.
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Fault codes from Vaillant that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.32 | Fan fault | The fan is faulty, blocked, or not connected; the electronics do not detect its rpm. Check the connector/harness, ensure the impeller spins freely, Hall signal, and rpm in diagnostics; if there is no signal or it is out of tolerance, the fan (193593) is the cause. |
| F.33 | The pressure switch does not turn on | The fan does not start or does not generate enough depression to switch the air pressure switch. Check that the fan rotates and reaches the target rpm (diagnosis) and that when activated the pressure switch closes; if it does not switch despite correct draught, replace the fan (193593). |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Vaillant extractor 193593
- Catalogue reference
- 193593
- Brand
- Vaillant
- Type of part
- Extractor fans
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days