Filling Key Vaillant Turbocombi VMW 232 1 Ref. 014735
If you cannot refill water into the heating circuit or notice that it is continuously leaking water, you may need the filling key Vaillant Turbocombi VMW 232 1. This part allows you to maintain the proper pressure in the heating system. Its failure can cause pressure issues that affect the performance of the boiler. It is installed in models such as the Turbocombi VMW 232-1 and Turbocombi VMW 230-1, among others. It should be replaced when it shows leaks or does not function properly.
VAT included
Consult via WhatsAppVaillant boilers compatible with reference 014735
Filling key with reference 014735. Two confirmed compatibilities: Turbocombi VMW 232-1 and Turbocombi VMW 230-1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant Turbocombi VMW 232-1 | Vaillant | Contrasted |
| Vaillant Turbocombi VMW 230-1 | Vaillant | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 014735 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 014735. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve 014735 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You cannot recover the pressure of the heating circuit when opening the valve.
Cause: The internal mechanism is blocked by limescale and does not allow water to pass through even when you open the control.
Make sure that the mains water valve supplying the boiler is open before touching the filling valve.
- 02
The faucet drips or leaks water even when it's closed.
Cause: The blue cap and its mechanism have lost their seal due to wear on the internal seat.
Tighten the control carefully until it reaches the closed position; if it continues to drip, the part is worn out.
- 03
The control is seized and does not turn to open or close the water flow.
Cause: The accumulated limescale on the spindle blocks the rotation after a long period of disuse.
Try gently tapping it before forcing it; if it doesn't give, don't keep insisting.
- 04
The boiler repeatedly loses pressure and needs to be refilled often.
Cause: The valve does not close completely and allows water to escape slowly but steadily.
Mark the cold pressure level and check it after a few hours; if it always drops from the same place, it's the valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Vaillant 014735
- Catalogue reference
- 014735
- Brand
- Vaillant
- Type of part
- Filling valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Vaillant Turbocombi VMW 232-1 Manual (PDF)Document © Vaillant, provided as a technical reference.