Flow switch Beretta Kompakt 24 CSI 1 RW Z 38 Ref. R10022348
If no hot water comes out when you turn on the tap, you may need a Flusostato Beretta Kompakt 24 CSI 1 RW Z 38 Ref. R10022348. This flow detector is responsible for detecting the flow of water and activating the ignition for the production of domestic hot water (DHW). When it fails, hot water does not activate even when the tap is open, which can cause inconveniences in your home. It is installed in boilers from the Kompakt, Ciao, Super Exclusive, and Mynute ranges, among others. It is advisable to replace it when you experience these symptoms to restore the hot water supply.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10022348
Flow meter with reference R10022348. Eight confirmed compatibilities: Kompakt 24 CSI and Kompakt 24 CAI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Kompakt 24 CSI | Kompakt | Contrasted |
| Beretta Kompakt 24 CAI | Kompakt | Contrasted |
| Beretta Ciao 24 CSI | Hello | Contrasted |
| Beretta Ciao 24 CAI | Hello | Contrasted |
| Beretta Super Exclusive 24 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 24 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CSI | Super Exclusive | Contrasted |
| Beretta Mynute J 24 CSI | Mynute | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part R10022348 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10022348. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter R10022348 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You turn on the hot water tap and the boiler does not ignite, the water comes out cold.
Cause: The flow detector does not send the water flow signal to the control board, and it does not trigger the ignition for domestic hot water.
Check that the tap is providing normal flow and that the aerator or inlet filter is not blocked before touching the part.
- 02
The boiler turns on and off several times in a row while the hot water continues to run.
Cause: The palette or the micro switch of the detector is intermittently activated due to dirt, and the flow signal comes in and out.
Open and close the tap a couple of times and check if the ignition takes longer than usual or if it cuts off at regular intervals.
- 03
The boiler works well for heating but fails when requesting domestic hot water.
Cause: The flow detector only intervenes in the domestic hot water circuit, which is why the fault is limited to that function.
Confirm that the problem only occurs when opening a tap and not when activating the heating, to narrow down that the involved part is this one.
- 04
The display shows a fault code related to the flow rate or the flow sensor.
Cause: The control unit detects an out-of-range signal from the sensor and blocks the start for safety reasons.
Note the exact code and check in your model's manual if it corresponds to the flow sensor before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Flow meter sheet Beretta R10022348
- Catalogue reference
- R10022348
- Brand
- Beretta
- Type of part
- Flow detectors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Beretta Mynute J 24 CSI Manual (PDF)Document © Beretta, provided as a technical reference.