Ebm-papst Gas Valve For Viessmann Vitodens 100-W Ref. GB-NO 055 E01 S00

Ebm-papst Gas Valve For Viessmann Vitodens 100-W Ref. GB-NO 055 E01 S00

Gas block manufactured by ebm-papst, as stated printed on the label ('Made by ebmpapst'). It regulates the gas flow to the burner in Viessmann Vitodens 100-W B1HC and B1KC boilers of 19 and 26 kW. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not ignite or is locked due to a gas supply fault.

Type of part
Gas valves
Catalogue reference
7861580
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Viessmann boilers compatible with reference 7861580

Gas valve with reference 7861580. Two confirmed compatibilities: Vitodens 100-W B1HC and Vitodens 100-W B1KC.

Proven compatibility

Boiler modelFamilyVerification
Viessmann Vitodens 100-W B1HCVitodens 100-WContrasted
Viessmann Vitodens 100-W B1KCVitodens 100-WContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 7861580 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 7861580. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 7861580

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and remains locked because gas is not reaching it.

    Cause: The gas block does not open the passage to the burner.

    Check that the gas valve is open and that power is reaching the control board before replacing it.

  • 02

    A buzzing or strange noise is heard in the area of the gas block.

    Cause: The internal coil vibrates due to a power supply fault or a shutter that does not seat properly.

    Check that the connection wiring to the block is not loose or damaged before replacing the part.

  • 03

    There is a smell of gas near the block, even though the boiler is working.

    Cause: A joint or connection of the gas block is losing tightness.

    Locate the exact point with soapy water; it could be a loose joint, not the entire block, before replacing it.

  • 04

    The boiler repeatedly locks out when trying to start.

    Cause: The unit does not provide the necessary gas flow for flame detection.

    Check the gas pressure in the installation before assuming that the block is faulty.

Viessmann fault codes that require diagnosis

CodeFaultTechnical checks
F8Burner fault: the (combined) gas valve closes too late.A faulty gas valve delays its closure during the safety test, and the control detects it and locks out. Check in service mode/minimum power by observing the closure delay, measuring the signal to the valve, and performing a tightness/closure test.
F4Burner fault: no flame signal (ionization not detected).If the gas valve does not open or delivers insufficient flow, the flame is not established and F4 appears. Check by measuring voltage at the valve coils during ignition and the gas pressure/flow; confirm opening from the service menu/function.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Viessmann 7861580

Catalogue reference
7861580
Uniclima internal SKU
VGCVV100
Brand
Viessmann
Type of part
Gas valves
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
ebm-papst (printed 'Made by ebmpapst')
Maximum pressure
85 mbar
Voltage/frequency
220V RAC, 50/60 Hz
Power
9.8 VA
Ambient temperature
0°C to 60°C
Degree of protection
IP40
Class
Kl.B/Kl.C/Gr.2
CE marking
CE-0085CM0036
Standard
DIN EN 126
Frequently Asked Questions

Frequently asked questions about the gas valve 7861580

Does this ebm-papst valve fit my Viessmann Vitodens 100-W B1HC of 26 kW?
Yes, it is among the compatible models: B1HC of 19 and 26 kW and B1KC of 26 kW.
Is the gas valve of the Vitodens 100-W manufactured by Viessmann or a third party?
The factory ebm-papst, as stated on the label itself ('Made by ebmpapst'), is not a part manufactured by Viessmann.
What voltage does this valve of the Vitodens 100-W operate at?
220V RAC at 50/60 Hz according to the label; the format of this indication is unusual and is transcribed literally.
When should this gas valve be replaced in a Vitodens 100-W B1KC?
The technical diagnosis must confirm that it is necessary to replace it, even when the boiler does not ignite or is blocked due to a fault in the gas supply to the burner.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Ebm-papst Gas Valve For Viessmann Vitodens 100-W Ref. GB-NO 055 E01 S00