Fagor Gas Valve FC 24 24N Natur Honeywell Ref. MUC080066
Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with FC 24/24 N, FC 24/24 (ref. MUC080066). Includes a one-year warranty. Delivery time and cost are shown at checkout for the destination country.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MUC080066
Gas valve with reference MUC080066. Two confirmed compatibilities: FC 24/24 N and FC 24/24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FC 24/24 N | Fagor Natur FC 24/24 N | Contrasted |
| Fagor FC 24/24 | Fagor Natur FC 24/24 N | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part MUC080066 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MUC080066. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve MUC080066 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E5 | Ionisation fault. | A misadjusted or faulty Honeywell gas valve (gas block) can cause a weak/unstable flame and insufficient ionisation current; check CO2 regulation in the gas block and ensure the valve opens/modulates by measuring pressure and coil supply. |
| E6 | Detection of a parasitic flame. | If the gas valve remains partially open or leaks when it should be closed, the boiler detects a flame at rest; check the tight closure of the solenoid valves (leak test) and ensure they close during shutdown. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Fagor MUC080066
- Catalogue reference
- MUC080066
- Brand
- Fagor
- Type of part
- Gas valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days