Gas Valve 830 TANDEM 83AP7050/4 For Baxi Solo, Ideal 836/837 And Vokera
The gas valve 830 TANDEM 83AP7050/4 regulates and allows the flow of gas to the burner of the boiler under the command of the PCB. When it fails, the boiler does not ignite, there may be flame lockouts, or it exhibits poor modulation. It is compatible with Baxi Solo WM20/4 RS, WM30/4 RS, WM40/4 RS, WM50/4 RS, WM60/4 RS, Ideal 836 and 837, and Vokera boilers. It is recommended to replace it if you are experiencing these issues.
VAT included
Consult via WhatsAppCompatible Saunier Duval boilers
Gas valve. Eight confirmed compatibilities: Solo WM20/4 RS and Solo WM30/4 RS.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Solo WM20/4 RS | Baxi | Contrasted |
| Saunier Duval Solo WM30/4 RS | Baxi | Contrasted |
| Saunier Duval Solo WM40/4 RS | Baxi | Contrasted |
| Saunier Duval Solo WM50/4 RS | Baxi | Contrasted |
| Saunier Duval Solo WM60/4 RS | Baxi | Contrasted |
| Saunier Duval 836 | Ideal | Contrasted |
| Saunier Duval 837 | Ideal | Contrasted |
| Saunier Duval (valve reference 2139, replaces 2897) | Vokera | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve resolves
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite or locks out immediately upon trying.
Cause: The solenoid valves do not allow gas to flow to the burner when the control board gives the command.
Check that 220/240V power is reaching the gas valve at the moment of ignition before replacing it.
- 02
Sometimes it starts without any issues and other times it fails, without any changes in the installation.
Cause: If one of the solenoid valves fails intermittently, the ignition will be irregular.
Repeat several consecutive ignitions and note if the fault shows any pattern before declaring the gas valve defective.
- 03
It smells like gas near the valve, or it is noticeable that it doesn't close completely.
Cause: One of the solenoid valves does not close completely and allows some gas to pass through.
Apply soapy water to the body of the gas valve with the boiler turned off to locate the exact point of the leak before replacing it.
- 04
The flame varies in size on its own, rising and falling without touching the thermostat.
Cause: The pressure regulator in the gas valve does not maintain a stable output pressure to the burner.
If possible, measure the outlet pressure with a manometer before replacing the complete gas valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval gas valve.
- Brand
- Saunier Duval
- Type of part
- Gas valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Model
- 830 TANDEM
- Code
- 83AP7050/4
- Secondary code
- 1017720 / 0164
- Additional code (Cod.)
- 9B30834, Series/Class 141S
- Solenoid valves EV1/EV2 (or EV3)
- Class B, 220/240V~ 50Hz, 7.7/10.8VA
- Nominal flow rate (Qn)
- 4.8 m³/h
- Input pressure (P1)
- 60 mbar
- Modulation range (Pn)
- 2-50 mbar
- Gas certification
- ALLGAS
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Solo WM50/4 RS Manual (PDF)Document © Saunier Duval, provided as a technical reference.