Honeywell Gas Valve Domina/Domitop/New Elite/Domicompact - Ref. I39804880

Honeywell Gas Valve Domina/Domitop/New Elite/Domicompact - Ref. I39804880

Stock · 2 units

When you open the hot water tap or turn on the heating, the Honeywell Gas Valve Domina/Domitop/New Elite/Domicompact - Ref. I39804880 regulates and allows the flow of gas to the burner according to the instructions of the PCB. If this valve fails, you will notice that the boiler does not ignite, there may be flame lockouts or modulation issues. This component is compatible with several Ferroli models, such as the DOMINA F 24 E, DOMITOP F 30 E, and NEW ELITE F 24 E, among others. It is advisable to replace the valve when the mentioned symptoms occur to restore the functionality of the boiler.

VAT included

Compatibility

Cointra boilers compatible with reference I39804880

Gas valve with reference I39804880. 17 verified compatibilities: DOMINA F 24 E and DOMINA F 30 E.

Proven compatibility

Boiler modelFamilyVerification
Cointra DOMINA F 24 EFerroliContrasted
Cointra DOMINA F 30 EFerroliContrasted
Cointra DOMINA C 24 EFerroliContrasted
Cointra DOMINA C 30 EFerroliContrasted
Cointra DOMITOP F 24 EFerroliContrasted
Cointra DOMITOP F 30 EFerroliContrasted
Cointra DOMITOP C 24 EFerroliContrasted
Cointra DOMITOP C 30 EFerroliContrasted
Cointra DOMICOMPACT F 24FerroliContrasted
Cointra DOMICOMPACT C 24FerroliContrasted
Cointra DOMINA OASI C 24 EFerroliContrasted
Cointra DOMINA OASI C 30 EFerroliContrasted
Cointra DOMINA OASI F 24FerroliContrasted
Cointra DOMINA OASI F 30FerroliContrasted
Cointra NEW ELITE F 24 EFerroliContrasted
Cointra NEW ELITE F 30 EFerroliContrasted
Cointra FERELLA 24 MELFerroliContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. I39804880 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference I39804880. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve I39804880 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there is no sign of a flame attempt.

    Cause: The valve does not receive the command to open or does not respond, so gas does not reach the burner.

    Before replacing it, check that the control board is sending power to the gas valve (look at the connector) to rule out a fault in the PCB.

  • 02

    The boiler locks up just when starting, almost always when it is cold.

    Cause: The valve takes time to open and the control board does not detect the flame in time, locking out for safety.

    If the fault occurs more frequently when cold, check the condition of the ignition electrode before replacing the gas valve.

  • 03

    It smells like gas near the boiler, especially right after it turns off.

    Cause: The gas valve does not close properly and allows some gas to escape at the end of the cycle.

    Ventilate the area and call a technician to confirm the exact source with a detector before purchasing the part.

  • 04

    The flame goes out on its own halfway through combustion or decreases in power without you requesting it.

    Cause: The modulating part of the gas valve does not maintain a constant gas flow while operating.

    Check for any gas pressure drops caused by other appliances running at the same time before blaming the gas valve.

Fault codes for Cointra that this part resolves.

CodeFaultDiagnosis and solution
A01The burner does not ignite because there is no flame.The gas valve does not open or does not regulate properly, so gas does not reach the burner. Check if there is power to the valve when it tries to ignite, inspect the continuity of the coils, and measure the pressure and flow at the valve outlet with a manometer.
A09Problem with the gas valve.It could be an internal fault of the gas valve or the wiring (open coil, short circuit, or stuck valve). Check the continuity of the coils, the condition of the connectors, and whether the valve activates when receiving power. If it does not open, it needs to be replaced.
A16The gas valve is not working.It could be a fault with the gas valve or its power supply. Check the connectors and if power is reaching the valve; if it receives the signal but does not open or regulate, the valve needs to be replaced.
A62The gas valve is not communicating with the PCB.The valve is not receiving a signal from the PCB, which could be due to a wiring issue, damaged connectors, or a faulty valve. Check the continuity of the wiring and the voltages; if everything is fine and the problem persists, replace the valve or check the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Cointra I39804880

Catalogue reference
I39804880
Brand
Cointra
Type of part
Gas valves
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell
Country of manufacture
Netherlands (Made in the Netherlands)
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve I39804880

Is this Honeywell gas valve compatible with the Domina F 24 E boiler?
Yes, the Domina F 24 E is on the list of compatible boilers.
What fault does replacing this valve resolve in a Domitop C 24 E?
It is replaced when the boiler does not ignite, locks at startup, there is a gas leak, or the flame modulation fails.
Is this valve suitable for the Ferella 24 MEL?
Yes, the Ferella 24 MEL is on the list of compatible boilers, along with Domina, Domitop, New Elite, and Domicompact F/C 24-30 E.

Spare parts related to Cointra Ferroli

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Gas Valve Domina/Domitop/New Elite/Domicompact - Ref. I39804880