Honeywell Gas Valve V7335A5011 (VK4105M) Ref. 65100244

Honeywell Gas Valve V7335A5011 (VK4105M) Ref. 65100244

Honeywell V7335A5011 gas regulator, mounted on the Honeywell VK4105M valve body according to external documentation. It regulates the gas pressure to the burner, with a range of 1 to 37 mbar and a maximum consumption of 165 mA. Replacement requires first confirming the fault of the part through technical diagnosis, even when there is a failure in the gas supply or regulation and the boiler does not ignite or shuts down during operation.

Type of part
Gas valves
Catalogue reference
65100244
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Ariston boilers compatible with reference 65100244

Gas valve with reference 65100244. Ten verified compatibilities: Microgenus 23 MFFI and Microgenus 27 MFFI.

Proven compatibility

Boiler modelFamilyVerification
Ariston Microgenus 23 MFFIAristonContrasted
Ariston Microgenus 27 MFFIAristonContrasted
Ariston Microtec 23 MFFIAristonContrasted
Ariston Microtec 23 MIAristonContrasted
Ariston Microtec 27 MFFIAristonContrasted
Ariston Modula 23 MFFIAristonContrasted
Ariston Modula 23 MIAristonContrasted
Ariston T2/23 MFFIAristonContrasted
Ariston T2/23 MIAristonContrasted
Ariston EST 23 MIAristonContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 65100244 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 65100244. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 65100244

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, you can hear the spark igniter, but the flame does not catch.

    Cause: The gas valve does not allow gas to flow to the burner at the moment of ignition, and the control board does not detect a flame.

    Confirm that the main gas valve is open and that other gas appliances in the house are working before checking the gas valve.

  • 02

    The boiler turns on and off by itself after a few minutes, and then tries again.

    Cause: The gas supply is interrupted or fluctuates during operation, and the boiler protects itself by shutting down the burner.

    Note if the cut always coincides with the same demand, domestic hot water or heating, to narrow down whether it is the gas valve or another component of the gas circuit.

  • 03

    The flame rises and falls without you having touched anything, or it sounds different at times.

    Cause: The valve does not modulate the output pressure to the burner properly, and the gas flow varies irregularly.

    Check that the incoming gas filter is not dirty, as a clogged filter can cause the same symptom of irregular modulation.

  • 04

    The boiler gets locked due to an ignition fault and needs to be reset manually.

    Cause: Without sufficient gas in the burner, the flame detector does not confirm ignition within the safety time.

    Before changing the gas valve, check the ignition or ionization electrode and its wiring, as they can cause the same fault.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Ariston gas valve 65100244

Catalogue reference
65100244
Uniclima internal SKU
VGMT2LLS
Brand
Ariston
Type of part
Gas valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Honeywell
Part code
V7335A5011
Maximum current
165 mA
Pressure range
1-37 mbar
Associated valve body
Honeywell VK4105M (main body on which this regulator is mounted), according to 2 independent external sources
Frequently Asked Questions

Frequently asked questions about the gas valve 65100244

Is this Honeywell V7335A5011 gas valve compatible with the Microgenus 23 MFFI?
Yes, the Microgenus 23 MFFI is among the compatible models according to the boiler list for this part.
What fault does replacing this Honeywell gas valve in a T2/23 MFFI resolve?
It should be checked when there is a failure in the gas supply or regulation, and the boiler does not ignite or turns off during operation. Replacement requires a technical diagnosis.
What gas pressure does the Honeywell V7335A5011 regulate when mounted on the VK4105M?
It regulates between 1 and 37 mbar, with a maximum consumption of 165 mA, according to the label.
Is the VK4105M valve and the Honeywell V7335A5011 regulator the same part?
The V7335A5011 regulator is mounted on the VK4105M valve body; according to two independent external sources, both correspond to the reference 65100244.
How many models are compatible with the Honeywell V7335A5011 gas valve?
There are a total of 10 confirmed models that are compatible with this gas valve.
Where can I find the reference for this gas valve?
The reference for this valve is VGMT2LLS, which corresponds to the Honeywell gas valve V7335A5011.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model