SIT Gas Valve Body for Junkers Cerapur Comfort ZWBC30-2 C23 - Ref. 87160115000
Refurbished Junkers Gas valves SIT

SIT Gas Valve Body for Junkers Cerapur Comfort ZWBC30-2 C23 - Ref. 87160115000

Gas valve body manufactured by SIT, not by Junkers, although it is installed in Cerapur and Cerapur Comfort boilers. It incorporates a double solenoid valve (EV1 and EV2, 31 VDC) that regulates the pressure and the flow of gas to the burner according to the boiler's demand. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler loses flame, does not modulate gas, or shows ignition error.

Type of part
Gas valves
Catalogue reference
87160115000
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Junkers boilers compatible with reference 87160115000

Gas valve with reference 87160115000. 17 verified compatibilities: ZWBC24-2 C and ZWBC25-2 C.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWBC24-2 CCerapur Comfort (ZWBC)Contrasted
Junkers ZWBC25-2 CCerapur Comfort (ZWBC)Contrasted
Junkers ZWBC25Cerapur Comfort (ZWBC)Contrasted
Junkers ZWBC28-2 CCerapur Comfort (ZWBC)Contrasted
Junkers ZWBC30-2 C23Cerapur Comfort (ZWBC)Contrasted
Junkers ZB14-1 ABZWB / ZB (series -1)Contrasted
Junkers ZB14-1 AIZWB / ZB (series -1)Contrasted
Junkers ZB24-1 ABZWB / ZB (series -1)Contrasted
Junkers ZB24-1 AIZWB / ZB (series -1)Contrasted
Junkers ZWB24-1 ABZWB / ZB (series -1)Contrasted
Junkers ZWB24-1 AIZWB / ZB (series -1)Contrasted
Junkers ZWB24-1 EBZWB / ZB (series -1)Contrasted
Junkers ZWB24-1 EIZWB / ZB (series -1)Contrasted
Junkers ZWB28-1 AIZWB / ZB (series -1)Contrasted
Junkers ZWB28-1 EBZWB / ZB (series -1)Contrasted
Junkers ZWB28-1 EIZWB / ZB (series -1)Contrasted
Junkers ZWB28-3 C23 S2800ZWB series 3 (C23)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 87160115000 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87160115000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 87160115000

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler loses the flame during operation and needs to be reset.

    Cause: The solenoid valves do not maintain a stable gas flow and the flame goes out by itself.

    Check the wiring and connectors of the gas valve: a loose connection causes the same flame cut-off.

  • 02

    The display shows a fault code related to the gas valve or the burner.

    Cause: The PCB detects that the gas valve does not respond to the open or close command it receives.

    Note the exact code displayed on the screen; it helps to confirm whether it points to the gas valve or another component before purchasing it.

  • 03

    The burner does not reach the power requested by the boiler and heats very little.

    Cause: A fault in the gas valve regulation limits the gas flow even though the boiler demands more.

    Check the incoming gas pressure: if it is low, it may seem like a fault with the gas valve when it is not.

  • 04

    There is no way to turn on the boiler, it doesn't even try to ignite.

    Cause: The valve body does not open either of the two solenoid valves, and gas does not reach the burner.

    Check that power is reaching the gas valve at the moment of ignition before replacing it.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
EAIgnition/ionisation fault: flame not detected.If the gas valve (body 87160115000) does not open or its coils are damaged, gas does not reach the burner and there is no ionisation signal. Check the voltage at the connector during the ignition attempt and the coil resistance; if voltage is present and it does not open, replace the valve.
F0 V 238Internal error: gas valve connection cable, gas valve, or control board defective.The self-check detects a fault in the gas valve circuit/operation (wiring, coils, or body). Verify continuity of the harness and resistance of the coils; if the gas valve test fails, replace the valve 87160115000.
FAAfter the gas disconnection: the flame is still detected.Internal leak/defective closure of the gas valve (e.g., EV2) keeps the flame after the stop command. Check ionisation current after shutdown and perform a tightness test on the valve; if it fails, replace the body 87160115000.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Junkers 87160115000

Catalogue reference
87160115000
Uniclima internal SKU
VGCCZWBC30
Brand
Junkers
Type of part
Gas valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
SIT (Sit S.p.A., Padua, Italy)
SIT internal code
0848105
Printed OEM code
8-716-011-500 (8716011500)
Maximum inlet pressure (Pi max)
60 mbar
Regulated output pressure (Po)
0.5-12 mbar
EV1
31 VDC, 7.7 VA class B
EV2
31 VDC, 3 VA class C
Air/gas ratio
1:1
Ambient temperature
0/60 °C
Before purchasing
  • The actual manufacturer of this component is SIT, not Junkers/Bosch; the boiler incorporates it as an integrated part.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve 87160115000

Is this valve body suitable for the Junkers ZWB24-1 AB?
Yes, it is compatible with the ZWB / ZB range (series -1), which includes models such as ZB14-1 AB and ZWB24-1 AB; please check your exact model.
What fault of the Cerapur Comfort ZWBC30-2 C23 indicates that this valve body needs to be replaced?
It should be checked when the boiler loses flame or shows a fault on ignition. Replacement requires a technical diagnosis.
What voltage do the solenoid valves of this valve body for the Junkers ZWB28-3 C23 S2800 operate on?
31 VDC: EV1 at 7.7 VA class B and EV2 at 3 VA class C.
How many models are compatible with this SIT gas valve body?
This valve body is compatible with a total of 17 models.
What is the reference for this valve body for the Junkers Cerapur Comfort ZWBC30-2 C23?
VGCCZWBC30 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
What fault codes are documented for this product?
The documented fault codes are EA, F0 V 238, and FA.