Vaillant Ecotec Plus Gas Valve VUW 246 5 5 824 Ref. 0020148381
Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with ecoTEC plus 824 (VUW 246/5-5), ecoTEC plus 831 (VUW 316/5-5), ecoTEC plus 837 (VUW 376/5-5) (ref. 0020148381). Includes a one-year warranty. Delivery time and cost are shown at checkout for the destination country.
VAT included
Consult via WhatsAppVaillant boilers compatible with reference 0020148381
Gas valve with reference 0020148381. Eight confirmed compatibilities: ecoTEC plus 824 (VUW 246/5-5) and ecoTEC plus 831 (VUW 316/5-5).
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant ecoTEC plus 824 (VUW 246/5-5) | Vaillant ecoTEC plus (VUW combi) | Contrasted |
| Vaillant ecoTEC plus 831 (VUW 316/5-5) | Vaillant ecoTEC plus (VUW combi) | Contrasted |
| Vaillant ecoTEC plus 837 (VUW 376/5-5) | Vaillant ecoTEC plus (VUW combi) | Contrasted |
| Vaillant ecoTEC plus 612 (VU 126/5-5) | Vaillant ecoTEC plus (VU heating only) | Contrasted |
| Vaillant ecoTEC plus 615 (VU 156/5-5) | Vaillant ecoTEC plus (VU heating only) | Contrasted |
| Vaillant ecoTEC plus 618 (VU 186/5-5) | Vaillant ecoTEC plus (VU heating only) | Contrasted |
| Vaillant ecoTEC plus 624 (VU 246/5-5) | Vaillant ecoTEC plus (VU heating only) | Contrasted |
| Vaillant ecoTEC plus 630 (VU 306/5-5) | Vaillant ecoTEC plus (VU heating only) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 0020148381 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020148381. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve 0020148381 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Fault codes from Vaillant that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.26 | Fuel valve not functioning. | The stepper motor/actuator of the gas valve is disconnected or faulty; check the power supply and continuity of the actuator and harness to the valve connector. |
| F.27 | Flame simulation (flame detection when it shouldn't). | The leaking gas solenoid valve may allow gas to pass when the burner is off; check the valve's tightness/closure (closure test) and rule out moisture in the electronics. |
| F.28 | Ignition fault on start-up. | The faulty/closed gas valve prevents supply during the spark; check the opening order (voltage at connector) and gas pressure/flow during the ignition sequence. |
| F.29 | Flame loss during operation (failed re-ignition). | A fault/intermittency in the gas valve or its adjustment can cut or fail to modulate the flow; check modulation/stability of pressure and wiring to the valve. |
| F.53 | Combustion regulation fault / unexpected gas mass. | The gas valve does not properly regulate the requested flow; check dynamic pressure, Venturi/mass sensor, and valve operation. |
| F.54 | Gas supply fault (start-up) / insufficient gas. | A faulty gas valve may not allow passage despite having pressure; check inlet pressure and effective opening of the valve during start-up. |
| F.56 | Fault in combustion component (CO protection/regulation). | Defective contact or fault in the gas valve; if after checking the wiring the fault reappears, the valve is considered defective. Verify control signal, continuity/insulation, and modulation response. |
| F.61 | Fault in the activation/command of the gas valve. | Coils to ground/short circuit or faulty valve prevent its operation; check control voltage at connector, continuity/insulation of coils, and if there is correct signal and it does not open, replace the valve. |
| F.62 | Delay in the closing of the gas valve. | Internal leak or stuck solenoid cause the flame to take time to extinguish; check that the ionisation signal drops when closure is commanded and perform a valve tightness/closure test. |
| F.88 | Fault: gas valve (connection). | The valve is disconnected/improperly connected or there is a short circuit in the harness; check the plug, polarity, and continuity of the wiring to the valve assembly. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Vaillant 0020148381
- Catalogue reference
- 0020148381
- Brand
- Vaillant
- Type of part
- Gas valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days