Chaffoteaux Pigma Green 25 Motor
The Chaffoteaux Pigma Green 25 motor is an actuator responsible for moving the 3-way valve in the boiler. Its function is to allow the correct distribution of hot water for heating and domestic hot water. When this part fails, you will notice that there is no heating or hot water, and you might see the fault codes 40-50-60-80. This motor is compatible with several boilers, including Pigma 25 FF, Pigma 30 FF, Talia 25 FF, and Urbia 25 FF, among others. It should be replaced when it shows faults in the operation of the heating or hot water system.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61302483-01
Motor with reference 61302483-01. 23 verified compatibilities: Alixia 24 FF and Alixia 24 CF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Alixia 24 FF | Alixia | Contrasted |
| Chaffoteaux Alixia 24 CF | Alixia | Contrasted |
| Chaffoteaux Pigma 25 FF | Pigma | Contrasted |
| Chaffoteaux Pigma 30 FF | Pigma | Contrasted |
| Chaffoteaux Talia 25 FF | Talia | Contrasted |
| Chaffoteaux Talia 30 FF | Talia | Contrasted |
| Chaffoteaux Talia Green 25 FF | Talia | Contrasted |
| Chaffoteaux Talia Green 30 FF | Talia | Contrasted |
| Chaffoteaux Urbia 25 FF | Urbia | Contrasted |
| Chaffoteaux Urbia 30 FF | Urbia | Contrasted |
| Chaffoteaux Niagara C 25 FF | Niagara | Contrasted |
| Chaffoteaux Niagara C 30 FF | Niagara | Contrasted |
| Chaffoteaux Centora 2.24 FF | Centora | Contrasted |
| Chaffoteaux Centora 2.28 FF | Centora | Contrasted |
| Chaffoteaux Clas 24 FF | Clas (Ariston) | Contrasted |
| Chaffoteaux Clas 28 FF | Clas (Ariston) | Contrasted |
| Chaffoteaux Genus 24 FF | Genus (Ariston) | Contrasted |
| Chaffoteaux Genus 28 FF | Genus (Ariston) | Contrasted |
| Chaffoteaux Egis 24 FF | Egis (Ariston) | Contrasted |
| Chaffoteaux Egis Plus 24 FF | Egis (Ariston) | Contrasted |
| Chaffoteaux BS 24 FF | BS (Ariston) | Contrasted |
| Chaffoteaux BS II 24 FF | BS (Ariston) | Contrasted |
| Chaffoteaux Matis 24 FF | Matis (Ariston) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 61302483-01 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61302483-01. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the motor 61302483-01 resolves.
The motor drives the corresponding component of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The domestic hot water comes out lukewarm or cold even though the radiators are heating well.
Cause: The motor is not correctly moving the mechanism that distributes the water between heating and domestic hot water, which causes poor distribution.
Open a hot water tap and listen for a clicking or short buzzing sound from the motor when trying to switch to hot water.
- 02
A continuous buzzing sound is heard, as if the motor is trying to operate unsuccessfully.
Cause: The motor is straining because there is a jammed mechanism, usually due to the accumulation of scale or dirt.
Cut off the power to the boiler if you hear that constant buzzing to avoid damaging the motor and note when during the cycle it occurs.
- 03
The boiler takes longer than usual to switch from heating to domestic hot water, or it stays for a while without providing either.
Cause: The return spring has lost strength or the internal gear is worn, which slows down the position change.
Time how long it takes to heat the water when you turn on the tap; if it takes more than 20-30 seconds, it could be a problem with the motor.
- 04
Sometimes hot water comes out without having opened any domestic hot water tap.
Cause: The motor has not returned completely to its resting position and the mechanism is stuck halfway between the two circuits.
With the boiler in standby, without requesting heating or domestic hot water, check if the motor has reached its final position before considering its replacement.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 40-50-60-80 | 3-way valve (distribution) blocked in heating. | The motor of the 3-way valve (Elbi 61302483-01) does not actuate the shutter or gets stuck, the PCB detects that the valve remains in the heating position; verify by applying ~230 V to the motor and checking CH↔DHW switching/shaft travel or measuring coil continuity. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux Motor Datasheet 61302483-01
- Catalogue reference
- 61302483-01
- Brand
- Chaffoteaux
- Type of part
- Motors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage
- 220V - 240V
- Frequency
- 50 Hz
- Temperature class
- T70
- Return type
- SPRING (spring return)
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux Niagara C 25 FF Manual (PDF)Document © Chaffoteaux, provided as a technical reference.