Airsol HKB 224 PCB Ref. 3001060232

Airsol HKB 224 PCB Ref. 3001060232

Stock · 4 units

The Airsol HKB 224 PCB Ref. 3001060232 is used in boilers from the Heatline Compact range, such as the S24 and S30 models, among others. This board is the component that controls the ignition, burner modulation, pump, and safety functions of the boiler. If it has faults, you will notice that the boiler does not start, locks out, or behaves erratically. It is advisable to replace it when errors such as F63, F64, F65, F67, or F70 appear, as they indicate problems with the memory or the signal of the board.

VAT included

Compatibility

Airsol boilers compatible with reference 3001060232

PCB with reference 3001060232. Four confirmed compatibilities: S24 and S24S.

Proven compatibility

Boiler modelFamilyVerification
Airsol S24Heatline Compact (non-condensing / Airsol HK B124)Contrasted
Airsol S24SHeatline Compact (non-condensing / Airsol HK B124)Contrasted
Airsol S30Heatline Compact (non-condensing / Airsol HK B124)Contrasted
Airsol S30SHeatline Compact (non-condensing / Airsol HK B124)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 3001060232 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 3001060232. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 3001060232 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The control panel with the screen goes dark, but when touching the boiler's panel, it is noticeable that it still has power.

    Cause: The display is a separate module that receives data from the PCB via a flat cable; if that connection fails, the screen turns off even though the board continues to operate.

    Disconnect and reconnect the flat cable properly at both ends and check that there are no bent pins.

  • 02

    No button on the remote does anything, neither power on nor temperature adjustment.

    Cause: If the main PCB does not process the commands, the display module may remain lit but unresponsive.

    Measure with a multimeter that the PCB is receiving the 230V input and that the fuse is not blown before replacing it.

  • 03

    The boiler ignites, runs for a while, and then stops on its own without any fault code being triggered.

    Cause: An internal fault in the PCB can lose the flame maintenance signal without generating a recognizable fault code.

    Cut the power for a couple of minutes and restart to rule out a temporary blockage before declaring the PCB faulty.

  • 04

    The display flickers or shows random characters that do not form any stable code.

    Cause: It is usually a false contact between the PCB and the display module due to the flat cable connector, not a fault of the display itself.

    Carefully move the flat cable while the boiler is on and observe if the blinking changes; if so, the problem is in the connection, not in the PCB.

Fault codes for Airsol that this part resolves.

CodeFaultDiagnosis and solution
F63Fault in the main PCB memoryThe EEPROM/circuitry of the PCB is corrupted or out of tolerance; if sensors and wiring are correct and the error reappears after a reset, the board is the cause. Check PCB voltages and rule out wiring/display faults before reprogramming or replacing.
F64Fault in the main PCB / rapid fluctuation of the flow/return sensorThe PCB electronics interpret erratic readings from the NTC due to input/ADC failure; if the NTC and its wiring measure correctly, the cause is the PCB. Confirm with ohmic measurement of the NTC and continuity to the PCB.
F65Excessive temperature of the main PCBThe internal thermal sensor of the PCB detects overheating due to dissipation failure or the circuit itself; if there is no external overheating, the board is defective. Check ventilation/location and actual temperature; if the fault code appears when cold, replace the PCB.
F67Flame signal fault on the main PCBThe ionization circuit of the PCB is not correctly processing the flame current; if the electrode, ground, and cable are correct and the signal is stable, the fault is in the control board. Check ionization microamps and continuity to the PCB.
F70User interface incompatible with the main PCB / incorrect product codeAfter changing the control board or display, the DSN/coding does not match between the UI and PCB; the board needs parameterization or is of incorrect reference. Verify that the DSN on the display matches the data plate and reprogram according to the manual; if it does not accept, incorrect board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the PCB Airsol 3001060232

Catalogue reference
3001060232
Brand
Airsol
Type of part
PCBs (control boards)
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Display module
Independent, connected to the PCB by flat cable.
Frequently Asked Questions

Frequently asked questions about the PCB 3001060232

Does this Airsol PCB Ref. 3001060232 work for my Heatline Compact S24S?
Yes, the Heatline Compact S24S is on the list of boilers compatible with this PCB.
Does the PCB for the Heatline Compact S30 include the control display?
Yes, the kit includes a control module and independent display, connected to the PCB by a flat cable, according to the available photos.
What is the difference between the display module of this PCB and the PCB itself in the Heatline Compact S24?
It only consists of a main board and a separate control/display module, connected to each other by a flat cable.

Spare parts related to Airsol Heatline Compact (non-condensing / Airsol HK B124)

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Airsol HKB 224 PCB Ref. 3001060232