Beretta Exclusive MIX 26 CSI PCB Ref. R10029772
RefurbishedBerettaPCBs (control boards)Finder (relays); EPCOS (blue component, varistor/capacitor)

Beretta Exclusive MIX 26 CSI PCB Ref. R10029772

Stock · 1 unit

If your boiler does not start or behaves erratically, the Beretta Exclusive MIX 26 CSI PCB Ref. R10029772 may be the solution. This component, manufactured by Finder and with reference R10029772, controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, errors such as 51: Electronic board or 52: Electronic board anomaly S may appear. It is compatible with several Beretta boilers, including Exclusive Mix 26 CSI, 30 CSI, 32 CSI, and 30 RSI, among others. It is recommended to replace it upon detecting issues in its operation.

VAT included

Compatibility

Beretta boilers compatible with reference R10029772

PCB with reference R10029772. Six confirmed compatibilities: Exclusive Mix 26 CSI and Exclusive Mix 30 CSI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Exclusive Mix 26 CSIBeretta Exclusive MixContrasted
Beretta Exclusive Mix 30 CSIBeretta Exclusive MixContrasted
Beretta Exclusive Mix 32 CSIBeretta Exclusive MixContrasted
Beretta Exclusive Mix 30 RSIBeretta Exclusive MixContrasted
Beretta Exclusive Micromix 26Beretta Exclusive MicromixContrasted
Beretta Exclusive Micromix 32 CSIBeretta Exclusive MicromixContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part R10029772 is the one for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10029772. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB R10029772 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites for hot water, but the heating pump does not start.

    Cause: The relay on the PCB that powers the pump is not closing the contact, although the rest of the board is functioning.

    Listen for the click of the relay when requesting heating; if you don't hear it, check the wiring and the capacitor of the pump.

  • 02

    The boiler does not ignite in any mode and the clicking sound of the gas valve is not heard when trying to start.

    Cause: The relay that controls the gas valve may not switch, preventing the opening from the source.

    Check the continuity of the gas valve coil with a multimeter before assuming that the fault is in the PCB.

  • 03

    The lock code appears and disappears on its own, without a clear pattern, especially when the boiler has been running for a while.

    Cause: The relay block heats up with use and some PCBs show intermittent faults that are corrected when they cool down.

    If the fault only appears with the boiler hot and resets well when cold, it points more to the PCB than to an external component.

  • 04

    The boiler heats the water well but not the heating, or vice versa: one of the two circuits is not responding.

    Cause: Each circuit depends on a different relay on the PCB, so one can fail without affecting the other.

    Before changing the PCB, confirm that the room thermostat is calling for heat correctly and that the three-way valve is not blocked.

Fault codes for Beretta that this part resolves.

CodeFaultDiagnosis and solution
51PCB (control board)General fault of the PCB AB01B (R10029772): loss of 5 V, internal corruption, or component fault. Check 230 V/5 V power supply, CN connectors, and continuity; if it persists, replace and parameterize the PCB.
52PCB anomaly SVariant of fault in the PCB (self-test/status S) indicating management failure in the PCB. Check voltages and grounds, bus between PCB and panel, and test with reference PCB.
53EEPROM R&W AnomalyRead/write error in the PCB EEPROM (service parameters). Try reprogramming the model parameters; if it doesn't save or reappears, the PCB memory is damaged and must be replaced.
54Parameter setting errorIncorrect parameters or unparameterized after replacing the PCB. Load the exact model configuration from the technical menu; if it does not accept or is lost, probable memory fault in the board.
55Parameter setting error SSame as 54 but in "S" variant; service parameters of the PCB not valid. Reprogram model parameters; if recording fails, replace PCB.
59PCB (control board)Specific alarm from the control board. Check 5 V, board-display communications, and relays/tracks; if everything is correct, the solution is to replace and parameterize the R10029772 PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta PCB R10029772

Catalogue reference
R10029772
Brand
Beretta
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Relay
Finder series 40.61, coil 24V (x4)
Blue block component
EPCOS
Frequently Asked Questions

Frequently asked questions about the PCB R10029772

Does this PCB Ref. R10029772 fit the Beretta Exclusive Micromix 26 AR?
Yes, the Exclusive Micromix 26 AR (1100993) is among the compatible models.
What relays are on the PCB of the Beretta Exclusive Mix 26 CSI?
Four Finder relays from the 40.61 series, with a 24V coil.
When should this PCB be replaced in a Beretta Exclusive Mix?
When the electronic management of the boiler fails.
Does the same PCB work for the Beretta Exclusive Mix 30 CSI and the 32 CSI?
Yes, the Mix 30 CSI/AR (1100933) and the Mix 32 CSI/AR (1100943) are on the list of compatible models, as well as the RSI versions.

Spare parts related to Beretta Beretta Exclusive Mix

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model