PCB Gruppo Giordano MP05 · 20047631 · Beretta 20049611 for Mynute Low NOx 24 CSI
To be confirmed: La MP05 gestiona el funcionamiento de la caldera: es su única PCB de gestión.
- Type of part
- Beretta
- Status
- Refurbished
- internal SKU
- PLBE021
- Warranty
- 1 year
Compatible Beretta boilers
Beretta. 18 compatibilidades contrastadas: Beretta Mynute S 24 CSI y Beretta Mynute S 28 CSI. Hay otros 7 modelos que todavía estamos comprobando.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Mynute S 24 CSI | Beretta | Contrasted |
| Beretta Mynute S 28 CSI | Beretta | Contrasted |
| Beretta Mynute S 28 CAI | Beretta | Contrasted |
| Beretta Mynute S 24 RSI | Beretta | Contrasted |
| Beretta Mynute S 35 CSI | Beretta | Contrasted |
| Beretta Mynute S 24 CSI E | Beretta | Contrasted |
| Beretta Mynute S 28 CAI E | Beretta | Contrasted |
| Beretta Mynute Special 24 CSI | Beretta | Contrasted |
| Beretta Mynute Sinthesi S 25 CSI | Beretta | Contrasted |
| Beretta Mynute Sinthesi S 29 CSI | Beretta | Contrasted |
| Beretta Mynute Sinthesi 25 CSI | Beretta | Contrasted |
| Beretta Mynute Sinthesi 29 CSI | Beretta | Contrasted |
| Beretta Ciao AT 29 CSI | Beretta | Contrasted |
| Beretta Riello Start 24 KI | Beretta | Contrasted |
| Beretta Riello Start 24 KIS | Beretta | Contrasted |
| Beretta Riello Start AR 25 KIS | Beretta | Contrasted |
| Beretta Riello Start AR 29 KIS | Beretta | Contrasted |
| Beretta Riello Start Aqua 24 BI | Beretta | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Beretta Mynute S 24 CAI and 24 CAI E | Beretta | Unconfirmed |
|---|---|---|
| Beretta Ciao S 24 CSI and 24 CAI | Beretta | Unconfirmed |
| Beretta Ciao AT 25 CSI | Beretta | Unconfirmed |
| Beretta Riello Start 24 Ki LN and 28 Ki LN | Beretta | Unconfirmed |
| Beretta Quadra II 24 CAI LX | Beretta | Unconfirmed |
| Beretta Riello Residence Externa 24 Ki LN | Beretta | Unconfirmed |
| Beretta Mynute Low NOx 24 CSI | Beretta | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the designation MP05 and the code 20047631 printed on the PCB.
- Check the circuit code 11600235 REV06 and, if they appear, 40002830 and CEPIN0694BT1901.
- If you have the breakdown of your boiler, look for the reference Beretta 20049611 (Riello 4R002783). Do not confuse it with 20084603 (boiler fault code).
- Check that your model is on the list of compatible ones.
- If they match, call us at 911 17 77 77 with the model of your boiler.
Beretta
- Uniclima internal SKU
- PLBE021
- Brand
- Beretta
- Type of part
- Beretta
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Marked module power supply
- 230Vac 50-60Hz
- Marked TP
- 1.5s
- TS marked
- 7.5s
- Inventory — Indicated reference
- 20049611
- Inventory — PCB Marking
- 94V-0 94V-0; 11600235 REV06
- Inventory — PCB Screen Printing
- 11600235; revision REV06
- Inventory — Application indicated in inventory
- Beretta MYNUTE LOW NOX 24 CSI
- Inventory — Marked code
- 20047631; CEPIN0694BT1901
- Datos adicionales — Fabricante de la tarjeta
- Giordano Controls, modelo MP05 ·
- Datos adicionales — Tiempo de encendido (TP)
- 1,5 s ·
- Datos adicionales — Tiempo de seguridad (TS)
- 7,5 s ·
- Datos adicionales — Versión
- Con display ·
- Identification — Marked designation
- MP05
- Identification — Marked code
- 20047631
- Identification — Marked code
- 40002830
- Identification — Marked code
- V0.0 REV0.0 MOD0.5
- Identification — Marked code
- 11600235 REV06
- Identification — Marked code
- I2 L2 M1
- Identification — Marked code
- CEPIN0694BT1901
- Technical sheet: Marked power supply module
- 230Vac 50-60Hz
- Technical sheet: TP marked
- 1.5s
- TS marked
- 7.5s
- Inventory data — Indicated reference
- 20049611
- Inventory data — PCB marking
- 94V-0
- Inventory data — PCB screen printing
- 11600235; revision REV06
- Inventory data — Application indicated in inventory
- Beretta MYNUTE LOW NOX 24 CSI
- Inventory data — PCB marking
- 94V-0; 11600235 REV06
- Inventory data — Marked code
- 20047631; CEPIN0694BT1901
- Pending applications to verify
- Beretta MYNUTE LOW NOX 24 CSI — compatibilidad anotada; pendiente de confirmar por variante. Declaraciones de (documentación 23/10/2026; revisión 24/10/2026), pendientes de confirmación por fabricante. Comprobar referencia, revisión y número de serie antes de usar: CIAO 20 CSI E · CIAO 24 CAI E · CIAO 24 CSI E · CIAO 28 CAI E · CIAO 28 CSI E
- Por confirmar: Beretta Mynute S 24 CAI y 24 CAI E
- Por confirmar: Beretta Ciao S 24 CSI y 24 CAI
- Por confirmar: Beretta Ciao AT 25 CSI
- Por confirmar: Riello Start 24 Ki LN y 28 Ki LN
- Por confirmar: Beretta Quadra II 24 CAI LX
- Por confirmar: Riello Residence Externa 24 Ki LN
- Do not confuse: 20084603 — Code for the Beretta Mynute Low NOx 24 CSI boiler — It is the one for the boiler in the listings, not the one for the PCB (20049611)
- indica para esta unidad la referencia 20049611 junto al código marcado 20047631. la 20049611 con la MP05; solo une también el 20047631.
- La 20049611 = MP05 la dan y la indica para esta unidad; la Mynute Low NOx 24 CSI sale en 3. Sin documento oficial. discrepan en si es original o compatible; la placa lleva marca Giordano Controls.
- Aplicaciones registradas pendientes de confirmar por modelo, variante o programación: Beretta Mynute Low NOx 24 CSI.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Beretta Mynute S 24 CSI Manual (PDF) Document © Beretta, provided as a technical reference.