Biasi Savio 120M PCB

Biasi Savio 120M PCB

Stock · 2 units

The Biasi Savio 120M PCB is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, become locked, or operate erratically. Users may notice faults such as E50, which indicates an OpenTherm communication anomaly, E89, which signals an internal error, or E99, which indicates that the board is not configured. This board is compatible with the Savio range, specifically with the 120M model. It is recommended to replace it when these symptoms or faults are detected.

VAT included

Compatibility

Biasi boilers compatible with reference 2000802038, S1047000

PCB with reference 2000802038, S1047000. A proven compatibility: 120M.

Proven compatibility

Boiler modelFamilyVerification
Biasi 120MSAVIOContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 2000802038, S1047000 is the part for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 2000802038, S1047000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 2000802038, S1047000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there is no response when the ignition command is given.

    Cause: If the control electronics are not functioning, no signal is sent to start, so the boiler does not respond.

    First, check the main power supply and the accessible fuses: if the PCB does not receive power, the problem is not with the electronics.

  • 02

    The panel controls do not respond to any presses.

    Cause: The microcontroller on the PCB interprets the pulses; if it gets stuck, the panel does not respond even though it seems to be working.

    Cut the power for 30 seconds and turn it back on: if the lockout occurs again, the fault is in the PCB.

  • 03

    The boiler intermittently locks up: sometimes it starts well and other times it does not respond.

    Cause: An intermittent fault in the control electronics usually indicates that the PCB is starting to fail.

    Keep a record of when the blockage occurs (when cold, when hot, during startup): this pattern helps confirm that it is the PCB and not another component.

Fault codes Biasi that this part solves

CodeFaultDiagnosis and solution
E50OpenTherm communication anomaly.Communication interface fault (OpenTherm) on the PCB or bus loss; verify by disconnecting the remote/OT, checking wiring and voltages at the OT terminals of the PCB; if it persists, the PCB is damaged.
E89Internal error (typically hardware).Internal fault of the PCB (micro/memory/regulators) or electrical network out of tolerance; check network quality and voltages 230V/5V/3.3V on the PCB, and if they are correct, replace the PCB.
E99PCB not configured.PCB not parameterized or with lost/incorrect configuration after replacement; verify and initialize parameters/model according to the manual (or BCC/ID if applicable); if it does not accept configuration, the PCB is defective.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Biasi PCB 2000802038, S1047000

Catalogue reference
2000802038, S1047000
Brand
Biasi
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Text printed on the PCB
IRIS1.0
Manufacturer of the integrated transformer
MYRRA
Frequently Asked Questions

Frequently asked questions about the PCB 2000802038, S1047000

Is MYRRA the manufacturer of the PCB for the Savio 120M?
No; MYRRA is the manufacturer of the transformer integrated into the PCB, a subcomponent, and does not identify the manufacturer of the complete board.
When should this PCB of the Savio 120M boiler be replaced?
It is the control electronics of the boiler; it is replaced when it fails.