Bertelli & Partners DU09.10 Advance Plus 25C ERP PCB - Ref. 15078.0006.0/0
PCB of the boiler manufactured by Bertelli & Partners, model DU09.10, with part number 15078.0006.0/0 printed on the circuit itself. It is the original component identified by its label; the material does not specify what specific function it performs within the boiler. Compatible with the boilers Advance Plus 25C ERP, Myto Condens Inox, and SIT M160.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- DECBMC2601
- Warranty
- 1 year
Compatible Biasi boilers
PCB. Three confirmed compatibilities: PLUS 25C ERP and CONDENS INOX.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi PLUS 25C ERP | ADVANCE | Contrasted |
| Biasi CONDENS INOX | MYTO | Contrasted |
| Biasi M160 (UI 0585-527) | SIT | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is completely unresponsive, with no lights or activity.
Cause: If the boiler's electronics fail, the unit may remain inactive even though it receives power.
First, check the main power supply and the fuses of the installation before considering the PCB as faulty.
- 02
A fixed fault code appears that cannot be reset.
Cause: The PCBs block the unit for safety when a fault is detected and require a reset.
Try resetting from the remote control or cutting the power for a few seconds before replacing the component.
- 03
The boiler operates intermittently, sometimes working well and other times it shuts off by itself.
Cause: A specific fault in the electronics can cause irregular interruptions without following a specific pattern.
Note at what point in the cycle it turns off; this helps to differentiate a PCB fault from a sensor fault.
- 04
The remote control or the panel do not detect the boiler, or there is a communication failure.
Cause: The boiler's electronics manage the communication between the panel, sensors, and components; a fault here interrupts that connection.
Check the connectors and cables between the PCB and the rest of the boiler before replacing it due to a communication issue.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Biasi PCB data sheet
- Uniclima internal SKU
- DECBMC2601
- Brand
- Biasi
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Manufacturer
- Bertelli & Partners
- Model
- DU09.10
- B&P code
- 16149
- OEM code / part
- 15078.0006.0/0
- Barcode / batch
- 330921UC0457
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Biasi MYTO CONDENS INOX Manual (PDF)Document © Biasi, provided as a technical reference.