Ferroli Divatop PCB F37 Ref. I39828411

Ferroli Divatop PCB F37 Ref. I39828411

70 €VAT includedIn stock · 3 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display does not respond. Compatible with Divatop F37, Divatop Low Nox F24, Divatop Low Nox F32 (ref. I39828411). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
I39828411
Brand
Ferroli
Type of part
PCBs (control boards)
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. I39828411) equips these models. Verified compatibility; check the reference before purchasing.

Divatop

  • Divatop F37
  • Divatop Low NOx F24
  • Divatop Low NOx F32
  • Divatop Micro F32
  • Divatop 60 F24
  • Divatop 60 F32

Ferdigit

  • Ferdigit PW F32
  • Ferdigit Micro F24
  • Ferdigit F24

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A02Flame signal present with burner offFlame detection circuit fault in the PCB interpreting a non-existent ionisation signal. First, check the electrode and wiring/grounding and measure ionisation current; if everything is correct, the PCB is damaged and must be replaced.
How do I know if this PCB is for my boiler?
Verify the reference I39828411 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Bertelli & Partners (B&P) - DBM03C part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Divatop F37

Scroll to the top