Bertelli & Partners PCB Ferroli Divatop Micro LN F24 Ref. 39828411
PCB for the Ferroli Divatop and Ferdigit range, in their 60, Micro, Low Nox, and standard variants. Manufactured by Bertelli & Partners (B&P), with their logo and code DBM03C appearing on the label of the PCB itself, powered at 230V. Sales reference: 39828411.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference 39828411
PCB with reference 39828411. 36 verified compatibilities: C24 and C32.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli C24 | Divatop Micro | Contrasted |
| Ferroli C32 | Divatop Micro | Contrasted |
| Ferroli F24 | Divatop Micro | Contrasted |
| Ferroli F32 | Divatop Micro | Contrasted |
| Ferroli C18 | Divatop Micro LN | Contrasted |
| Ferroli C24 | Divatop Micro LN | Contrasted |
| Ferroli C32 | Divatop Micro LN | Contrasted |
| Ferroli F24 | Divatop Micro LN | Contrasted |
| Ferroli F32 | Divatop Micro LN | Contrasted |
| Ferroli C24 | Divatop 60 | Contrasted |
| Ferroli C32 | Divatop 60 | Contrasted |
| Ferroli F24 | Divatop 60 | Contrasted |
| Ferroli F32 | Divatop 60 | Contrasted |
| Ferroli C24 | Divatop ST | Contrasted |
| Ferroli C32 | Divatop ST | Contrasted |
| Ferroli F24 | Divatop ST | Contrasted |
| Ferroli F32 | Divatop ST | Contrasted |
| Ferroli C24 | Ferdigit 60 | Contrasted |
| Ferroli C32 | Ferdigit 60 | Contrasted |
| Ferroli F24 | Ferdigit 60 | Contrasted |
| Ferroli F32 | Ferdigit 60 | Contrasted |
| Ferroli F37 | Ferdigit 60 | Contrasted |
| Ferroli C24 | Ferdigit Micro | Contrasted |
| Ferroli C32 | Ferdigit Micro | Contrasted |
| Ferroli F24 | Ferdigit Micro | Contrasted |
| Ferroli F32 | Ferdigit Micro | Contrasted |
| Ferroli F37 | Ferdigit Micro | Contrasted |
| Ferroli C18 | Ferdigit Micro LN | Contrasted |
| Ferroli C24 | Ferdigit Micro LN | Contrasted |
| Ferroli C32 | Ferdigit Micro LN | Contrasted |
| Ferroli F24 | Ferdigit Micro LN | Contrasted |
| Ferroli F32 | Ferdigit Micro LN | Contrasted |
| Ferroli C24 | Ferdigit PW | Contrasted |
| Ferroli C32 | Ferdigit PW | Contrasted |
| Ferroli F24 | Ferdigit PW | Contrasted |
| Ferroli F32 | Ferdigit PW | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 39828411 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39828411. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 39828411 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on: there are no lights or display, although there is power in the house.
Cause: The PCB distributes the 230V power to the other components; if its input fails, the unit does not receive power.
Check that the main switch and the installation fuse are okay, and inspect the fuse on the PCB before replacing it.
- 02
An error code appears on the display that repeats when trying to reset the boiler.
Cause: The PCB collects readings from the sensors and blocks operation if it detects an incorrect value.
Note the fault code: it often indicates a specific sensor or component, not the entire PCB, so check it in the manual before replacing it.
- 03
The boiler tries to ignite, you can hear the fan and a click, but the burner does not light.
Cause: The PCB controls the ignition sequence; if a relay or the ignition circuit fails, the sequence is interrupted.
Check for visible spark at the electrode during the attempt; if there isn't one, inspect the electrode and its cable before blaming the PCB.
- 04
The control does not operate the boiler: it does not change the temperature or the operating mode.
Cause: The PCB receives the commands from the control; if that part fails, the control may be fine but not function.
Test the manual mode of the boiler, if available, to see if it responds without the remote control before replacing the PCB.
- 05
The flame is unstable or the boiler modulates erratically, unrelated to the actual demand.
Cause: The PCB regulates the modulation of the flame according to the signals it receives; if its electronics fail, the modulation is not consistent.
Before changing the PCB, check the gas pressure and the condition of the burner, as an unstable flame can also be due to that.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| A02 | Flame signal present with burner off (flame detected when there shouldn't be one). | The DBM03C control board reads/generates a false ionisation signal with the burner off; the range documentation explicitly lists 'board anomaly' as the cause. Verify: first rule out dirty/poorly connected ionisation electrode and poor grounding; if the flame signal persists with the burner and electrode correct, the board is the cause and must be replaced. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli PCB 39828411
- Catalogue reference
- 39828411
- Brand
- Ferroli
- Type of part
- PCBs (control boards)
- Units in stock
- 8 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Supply voltage
- 230V
- PCB code (Bertelli & Partners)
- DBM03C