Junkers Euromaxx ZWC28-1MF2K PCB · 8748300455
It is the control board of the boiler: it manages the ignition, modulation, and safety features. It is suspected when the boiler does not ignite, does not respond to the panel, restarts by itself, or displays fault codes that do not match the fault.
- Type of part
- Junkers
- Status
- Refurbished
- internal SKU
- PLC253
- Warranty
- 1 year
Compatible Junkers boilers
Junkers. A proven compatibility: Junkers Euromaxx ZWC28-1MF2K.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers Euromaxx ZWC28-1MF2K | Junkers | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look at the PCB: it should have 8 748 300 printed and 465 written by hand. In our technical sheet, the complete code is 8748300455.
- Compare the models 1274-BF, 0251PY004, and HTII-3, the relay RT314024, and the protective screen T3.15A.
- Do not rely solely on the prefix 8 748 300 or HTII-3: the official lists mention other PCBs (454, 506; the 533, in an unassigned column 2892 not securely assigned to the ZWC28-1MF2K) and a different HTII-3 is from the -6 series. Compare the complete code.
- Check on the rating plate that your boiler is a Junkers ZWC28-1MF2K.
- If they match, call us at 911 17 77 77 with your boiler model and we will confirm if we have it.
Symptoms that require diagnosis in the junkers
Common symptoms and faults
- 01
Fault code F0: internal error of the PCB.
Cause: The official technical manual from Bosch 6720607122 indicates to replace the PCB. Have a technician confirm it before changing it.
- 02
Fault code F7: false ionization signal
Cause: The same manual lists ionization, the PCB, and moisture on the board as causes.
- 03
The boiler does not ignite, restarts or turns off by itself, or shows erratic faults.
Cause: Symptoms associated with the PCB of this boiler. Check the power supply and fuses first.
- 04
The display shows F0 and the boiler locks out.
Cause: Internal fault of the PCB. The boiler remains locked until the reset is pressed.
Note the fault code and reset the boiler. Have a technician confirm the fault and replace the PCB.
- 05
The display shows F7 and the boiler locks out.
Cause: False ionization signal. Possible causes are ionization, the PCB, or moisture on the board.
Check the ionization and if there is moisture on the PCB before replacing it. Have a technician confirm it.
Junkers fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F0 | Internal fault of the PCB. Boiler lockout until reset. | Replace the PCB. Have a technician confirm it before changing it. |
| F7 | False ionization signal. Boiler lockout until reset. | Possible causes: ionization, PCB or moisture on the board. Check the ionization and moisture before replacing the board. Have a technician confirm it. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Junkers
- Uniclima internal SKU
- PLC253
- Brand
- Junkers
- Type of part
- Junkers
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Protection screen printing
- T3.15A
- Inventory — Subcomponent relay
- RT314024
- Inventory — Subcomponent fuse
- F2.5A
- Inventory — Subcomponent condenser
- 470nM
- Inventory — Application indicated in inventory
- ZWC28-1MF2K
- Inventory — Marked code
- 1274-BF; 0251PY004; HTII-3; BB BA BG
- Printed PCB silkscreen
- 8 748300
- Handwritten suffix on PCB
- 465
- Stock code
- 8748300455
- Identification — Printed PCB silkscreen
- 8 748300
- Identification — Handwritten suffix on PCB
- 465
- Identification — Code on bag
- 8748300455
- Identification — Marked code
- 1274-BF; 0251PY004
- Identification — Marked code
- HTII-3; BB BA BG
- Technical sheet: Protection screen printing
- T3.15A
- Inventory data — Subcomponent relay
- RT314024
- Inventory data — Subcomponent fuse
- F2.5A
- Inventory data — Subcomponent condenser
- 470nM
- Inventory data — Application indicated in inventory
- ZWC28-1MF2K
- Inventory data — Marked code
- 1274-BF; 0251PY004; HTII-3; BB BA BG
- Additional markings
- CI NEC JAPAN: D1274 BF / 0251Y00. Relay: RT314024. Fuses: F2.5A and T3.15A. Capacitor marked 470nM (literal reading). Other codes: 1274-BF; 0251PY004; HTII-3; BB BA BG. PCB base 8 748 300 and handwritten suffix 465. Bag code: 8748300455.
- Pending applications to verify
- ZWC28-1MF2K — compatibility noted; pending confirmation by variant.
- F0 and F7 are listed in the official manual table 6720607122, which the official Bosch sheet links to the ZWC28-1MF2K23S2892. Check the code in your boiler's manual.
- Not compatible or excluded at source: Junkers ZWSE-4 — A distributor assigns another PCB: 8748300506
- Not compatible or excluded: Junkers ZWN18-6AE21 and ZWR24-6KE31 (series -6) — they use the PCB HTII-3 GZT3: 87483005540
- Do not confuse: 8 748 300 454 — PCB from the official Bosch list 6720611196 (ed. 02.10), which covers ZWC24/28-1MF2K — Another code: differs in the last digit. Do not consider them the same.
- Do not confuse: 8 748 300 506 — Official list plate 6720611196 (ed. 05.08) and 6720611197 — Another plate code from the same family.
- Do not confuse: 8 748 300 533 — PCB from the official Bosch list 6720611196 (ed. 05.08), in a column marked 2892 not assigned to the ZWC28-1MF2K — Another PCB code from the same family.
- Do not confuse: 8 748 300 449 — PCB from the J 1455 list of the ZWC24/28-1MFK — Another model (MFK) and another code
- Do not confuse: 87483005540 — HTII-3 GZT3 PCB from the ZSN/ZWN/ZWR/ZSR -6 series (German) — It also carries the HTII-3 brand, but it is from a different series and has a different code.
- without additional external confirmation read quote 8748300455. The official lists of the family provide other PCBs (454 and 506); the 533 appears in a column marked 2892 of the list 6720611196 (ed. 05.08) that we cannot confidently assign to the ZWC28-1MF2K. Always compare the printed code.
- Part, codes, and boiler confirmed. Without additional external confirmation, read quote 8748300455 (external level 0); the official lists provide other PCBs (454 and 506) and a 533 in a column marked 2892 from list 6720611196 (ed. 05.08) that we cannot confidently assign to the ZWC28-1MF2K.