Main PCB Ariston Cares Premium 24 EU Ref. 60002508 01
If your boiler does not start, locks up, or exhibits erratic behavior, it may be due to a fault in the Ariston Cares Premium 24 EU Main PCB Ref. 60002508. This board controls essential functions such as ignition, burner modulation, and the pump. When it fails, you may experience errors such as 3 03, 3 05, 3 06, or 3 07. It is compatible with Ariston Cares Premium and HS Premium models, as well as some from Chaffoteaux. You should replace it if you notice these symptoms or associated errors.
VAT included
Consult via WhatsAppAriston boilers compatible with reference 60002508 01
PCB with reference 60002508 01. Nine confirmed compatibilities: Inoa Green 24 EU and Inoa Green 29 EU.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston Inoa Green 24 EU | Chaffoteaux Inoa Green | Contrasted |
| Ariston Inoa Green 29 EU | Chaffoteaux Inoa Green | Contrasted |
| Ariston Inoa Green 30 | Chaffoteaux Inoa Green | Contrasted |
| Ariston CX Green 24 EU | Chaffoteaux CX Green | Contrasted |
| Ariston CX Green 29 EU | Chaffoteaux CX Green | Contrasted |
| Ariston Cares Premium 24 EU | Ariston Cares Premium | Contrasted |
| Ariston Cares Premium 30 EU | Ariston Cares Premium | Contrasted |
| Ariston HS Premium 24 EU | Ariston HS Premium | Contrasted |
| Ariston HS Premium 30 EU | Ariston HS Premium | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 60002508 01 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60002508 01. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 60002508 01 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler won't turn on, there are no lights or display, as if it were without power.
Cause: If the PCB does not start, there is no power reaching any component, even though the boiler has power at the input.
Measure with a multimeter that 230V is reaching the input of the PCB before declaring it faulty.
- 02
The display stays on but does not respond to any button on the panel.
Cause: The microprocessor on the PCB manages the controls; if it hangs, the screen remains on but does not respond to the command.
Try performing a general reset by leaving the boiler off for a few minutes before replacing the PCB.
- 03
A different fault code appears each time you try to turn it on, with no apparent relation between them.
Cause: When the electronic control fails, the codes it displays become unreliable because the fault lies with the generator.
Note the exact codes and compare them with the manual: if they don't match any logical fault, point to the PCB.
- 04
The thermostat or remote control fails to synchronize or communicate with the boiler.
Cause: Communication with the control passes through the module of the PCB; if it fails, the boiler does not receive a signal from the thermostat.
Test the temperature setting directly on the boiler's panel to rule out a fault with the control.
- 05
The boiler turns on, runs for a few minutes, and then stops on its own without any apparent reason.
Cause: An intermittent fault in the PCB can lose the control signal even if the rest of the installation is fine.
Check that the connectors on the PCB are properly seated and free of oxidation before replacing it.
Fault codes for Ariston that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 3 03 | Main PCB fault | Self-diagnosis detects an internal fault in the main control board (PCB). Check 230 Vac and 2A fuse, connectors, and bus/display; if power supply and wiring are correct, replace the board. |
| 3 05 | Main PCB fault | The main PCB reports an internal error (subcode 3 05). Check voltages, fuse, and connections; if there are no external anomalies, the cause is the PCB itself. |
| 3 06 | Main PCB fault | Internal fault detected in the PCB (subcode 3 06). Check power supply/wiring; if they are correct, confirm fault of the PCB with replacement/cross-test. |
| 3 07 | Main PCB fault | Boiler self-diagnosis indicates an internal error of the main PCB (subcode 3 07). Check 230 Vac network, 2A fuse, and connectors; if everything is correct, replace the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ariston PCB 60002508 01
- Catalogue reference
- 60002508 01
- Brand
- Ariston
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- voltage
- 12V
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ariston Cares Premium 30 EU Manual (PDF)Document © Ariston, provided as a technical reference.