Main PCB Chaffoteaux Siam 23 CF (TTL 200 I) Ref. 61002711

Main PCB Chaffoteaux Siam 23 CF (TTL 200 I) Ref. 61002711

Main PCB for Chaffoteaux Siam 23 CF, ref. 61002711 (screen-printed PCB 1 002 711, model TTL 200 I). It controls ignition, ionization, pump, and safety features (overtemperature, flue, minimum pressure). Valid for CF versions 220421/220431. Refurbished: always confirm by reading the board and parts list before replacement.

Catalogue reference
61002711
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Calderas Chaffoteaux compatible with reference 61002711

PCB with reference 61002711. Two confirmed compatibilities: SIAM CF P FR (220421) and SIAM CF N FR (220431).

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux SIAM CF P FR (220421)SiamContrasted
Chaffoteaux SIAM CF N FR (220431)SiamContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 61002711 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 61002711

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no spark or attempt to ignite; lock LED is on.

    Cause: Fault in the PCB or lack of power/blown fuse.

    Check the 230 V input, 2 A/250 V fuse, and ensure that the ignition module receives a signal from the PCB.

  • 02

    Spark is present but the gas valve does not open; there is no flame.

    Cause: Faulty gas relay/control on PCB or safety in open series.

    Check the continuity of the thermostat at 105 °C, smoke sensor at 80 °C, and minimum pressure switch; if they are OK and there is no control voltage, suspect the PCB.

  • 03

    Intermittent lockouts with a red LED and the need for a reset.

    Cause: Control fault on PCB or actual safety trip.

    Check probable causes (overheating/ventilation) and rule out hydraulic causes; if it persists without an external cause, PCB.

  • 04

    The pump works, but there is no ignition sequence.

    Cause: Logical fault of the PCB (TTL 200 I) or incoherent signal input.

    Check sensors, flow and pressure switch; if inputs are correct and it does not start the sequence, the PCB is faulty.

  • 05

    A 2 A fuse keeps blowing repeatedly.

    Cause: Short circuit on the PCB or on peripherals powered by it.

    Isolate loads (igniter, gas valve, pump) and measure consumption; if it continues to blow fuses with loads disconnected, PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: PCB electrónica Chaffoteaux 61002711

Catalogue reference
61002711
Uniclima internal SKU
PLCH024X
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Commercial reference
61002711
Silkscreen code on PCB
1 002 711 (1002711)
Logical model on PCB
TTL 200 I
Verified compatibility
Siam CF P FR (220421) and Siam CF N FR (220431)
Managed safety systems
Thermostat 105 °C (61002697), flue safety 80 °C (Spott), minimum pressure switch ~0.8 bar (995903)
Protection fuse
2 A, 250 V (60054442)
Before purchasing
  • Work on the boiler without power and turn off the gas before intervening.
  • Download static electricity and avoid short circuits when handling the PCB.
  • The flue circuit and the safety thermostats are not bridged; their continuity is only checked.
  • Replace gaskets and single-use components after disassembly.
  • Check the tightness and evacuation of combustion products at the end.
  • Do not replace with 61002907 (model FF); it is not compatible with CF.
  • After the change, check the settings and the correct operation of ignition/ionization.
Frequently Asked Questions

Frequently asked questions about the PCB 61002711

Does this PCB work for other models in the Siam range?
No. This main PCB (ref. 61002711) is specific to the SIAM CF P FR (220421) and SIAM CF N FR (220431) models.
Is it normal that my boiler does not display fault codes?
Yes. In the SIAM CF boilers, there are no numerical codes; the diagnosis is performed using LEDs and the verification of safety devices and signals.
How can I confirm that I have the reference 61002711?
Check the silkscreen on the PCB. It should read '1 002 711 / TTL 200 I'. This corresponds to the reference of the board for the SIAM CF models.
What reference should I look for if I need a PCB for a different model?
For the SIAM CF P FR (220421) and SIAM CF N FR (220431) models, you need to look for the reference PLCH024X.
How many models are compatible with this PCB?
The main PCB (control board) Chaffoteaux (ref. 61002711) is compatible with a total of 2 confirmed models.
Are there documented fault codes for this PCB?
No, there are no documented fault codes for this PCB.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Main PCB Chaffoteaux Siam 23 CF (TTL 200 I) Ref. 61002711