Main PCB Junkers Cerapur Compact ZWB 24-1/28-1 (Heatronic 3 Z 10003) Ref. 8 737 702 723
RefurbishedPCBs (control boards)Bosch Thermotechnik GmbH (Junkers)

Main PCB Junkers Cerapur Compact ZWB 24-1/28-1 (Heatronic 3 Z 10003) Ref. 8 737 702 723

VAT includedStock · 1 unit

Main PCB Heatronic 3 (Z 10003) for Junkers Cerapur Compact ZWB/ZSB -1. It manages ignition, pump, fan, gas valve, and sensors. Useful when faults F0, A8, AC, b1, or EA appear and after ruling out sensors/wiring. Refurbished part with reference 8 737 702 723.

Compatibility

Junkers boilers compatible with reference 8 737 702 723

PCB with reference 8 737 702 723. Two confirmed compatibilities: ZWB 24-1 DE 23 and ZWB 28-1 DE 23.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWB 24-1 DE 23Cerapur CompactContrasted
Junkers ZWB 28-1 DE 23Cerapur CompactContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 8 737 702 723 is the part for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 8 737 702 723

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    F0 recurring or random

    Cause: Internal fault of the Heatronic 3 PCB

    Cut power, check connectors and bus; if F0 reappears with peripherals OK, replace the PCB.

  • 02

    b1 when turning on after maintenance

    Cause: Incorrectly connected encoder or faulty reading on PCB.

    Re-seat/measuring the encoder; if OK, the encoder input on the PCB may be damaged.

  • 03

    A8/AC with connected modules/controllers

    Cause: Fault in Heatronic communication channel (PCB)

    Test with another cable/bus; if the module works in another boiler, replace the PCB.

  • 04

    EA lock with spark and correct gas

    Cause: Ignition/ionization stage on degraded PCB

    Check electrodes and ground; if correct and without a recognized flame, check the PCB.

  • 05

    E9 despite being bled and with the pump operational

    Cause: Erratic reading of NTC or thermal control on PCB

    Measure NTC and continuity; check 24/5 V fuses on the PCB; if okay, replace the PCB.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
F0Internal electronics faultCheck the plugs and bus module; if the issue persists, replace the PCB/module according to the manual. Directly related to the main board.
A8Communication interrupted (bus)Check the wiring between the bus module and Heatronic; if the bus and peripherals are correct, there may be a fault in the PCB.
ACModule not detectedCheck the connection between the module and the Heatronic; if the module is OK, suspect the communication channel on the PCB.
b1Encoder connector not detectedSet/measure the encoder connector that identifies the model; if correct and still b1, likely fault in the PCB.
EAFlame not detected (ignition lock)Check gas, pressure, electrodes, and wiring; if spark/ionization are correct, check ignition stage/flame reading on the PCB.
E2Faulty outgoing NTCMeasure the NTC and its cable; if the values are correct, the analog input on the PCB may be damaged.
E9Overtemperature trip on supplyBleed the system and check the pump; check the 24 V fuse on the PCB. If the hydraulics are correct, check the PCB.
F7/FAFlame detected with burner off / false flame after closing gasDry/check electrodes and siphon; if false signal persists, check ionization circuit on the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers PCB 8 737 702 723

Catalogue reference
8 737 702 723
Uniclima internal SKU
PECZWBC28X
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Control platform
Bosch Heatronic 3 (screen printing Z 10003)
Reference on PCB
8 737 702 723 (8737702723)
Equivalents/substitutes
8737707762; 8748300488 (supply/kit); 87377074270; 86389001340
Fuses in electronics
T 2.5 A AC 230 V; T 1.6 A DC 24 V; T 0.5 A DC 5 V (on PCB)
Verified compatibility
Cerapur Compact ZWB 24-1 DE 23; ZWB 28-1 DE 23 (ZSB/ZWB -1)
Managed functions
Ignition, flame detection, fan, pump, gas valve, NTC readings, and bus.
Before purchasing
  • Absolute cut-off of power and gas before intervening; verification of absence of voltage.
  • Electrostatic discharge (ESD): handle the PCB with an anti-static wrist strap/mat.
  • Bleeding the circuit after the replacement to avoid E9 due to air and overheating.
  • Replace gaskets and single-use cable glands if associated elements are disassembled.
  • Check and replace fuses with the same type/value; investigate the cause of the trip.
  • Parameterization: check/adjust service functions of Heatronic 3 after replacement.
  • Wiring and connectors: do not force; respect the guidelines and codifications of the original harness.
Frequently Asked Questions

Frequently asked questions about the PCB 8 737 702 723

Is this PCB compatible with my Junkers Cerapur Compact boiler?
Yes, it is compatible with the models ZWB 24-1 DE 23 and ZWB 28-1 DE 23.
My boiler shows the fault code EA, could it be the PCB?
Yes, if you have already verified that the gas and the spark are correct, the PCB may be failing in the ignition or flame detection stage.
What reference should I look for if I need to replace my PCB?
The correct reference is PECZWBC28X, which corresponds to the main PCB of the Junkers Cerapur Compact.
How many models are compatible with this PCB?
The PCB is compatible with a total of 2 confirmed models: ZWB 24-1 DE 23 and ZWB 28-1 DE 23.
Do I need to reprogram anything after changing the PCB?
Yes, it is advisable to check the service parameters of Heatronic 3 and adjust the power/domestic hot water according to the manual.
I have seen other references like 87377074270, are they equivalent?
Yes, they are documented earlier variants for ZWB 24-1 and can be replaced by 8 737 702 723.
Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Main PCB Junkers Cerapur Compact ZWB 24-1/28-1 (Heatronic 3 Z 10003) Ref. 8 737 702 723