Main PCB Saunier Duval ThemaClassic F 25 E Ref. S10470

Main PCB Saunier Duval ThemaClassic F 25 E Ref. S10470

Stock · 1 unit

The Main PCB Saunier Duval ThemaClassic F 25 E, with manufacturer reference 0310144400L12, is a component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or exhibit erratic behavior. This part is compatible with several boiler models, including the ThemaClassic F 25 E, F 24 E, C 24 E, C 25 E, among others. It is recommended to replace it upon detecting faults such as F13, F11, F12, or F18, which indicate issues in the printed circuit board or in the user interface signal.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S10470

PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S10470 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S10470 resolves

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on: there is no display, lights, or sound.

    Cause: The PCB does not receive or distribute power to the control circuits.

    Check the main fuse and measure with a multimeter that 230V is reaching the input of the PCB before replacing it.

  • 02

    An error code appears on the display that persists after resetting the boiler.

    Cause: The PCB keeps the lock because it continues to detect the fault of the component it monitors.

    Note the exact code and first check the component indicated (sensor, pressure switch, electrode) before considering that the PCB is faulty.

  • 03

    The boiler starts in manual mode but does not respond to the thermostat or the remote control.

    Cause: Problem in the part of the PCB that receives the heat demand signal.

    Check the wiring of the thermostat and try to directly bridge its terminals on the PCB before suspecting it.

  • 04

    It works for a while and then turns off by itself, always after a similar period of use.

    Cause: Microcut on the PCB: a component fails when heated and recovers when cooled down.

    Time the cut if it always occurs at the same operating time; that pattern suggests that the problem is with the PCB more than with another cause.

  • 05

    The pump or the burner does not start even though the boiler requests heat.

    Cause: The output relay of the PCB does not close the contact that provides power to that component.

    Measure with the multimeter if there is power at the pump or valve output when it should be activated, before replacing the PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S10470 PCB.

Catalogue reference
S10470
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
24V
current
6A
supply voltage
230V
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S10470

Does this PCB work for the Saunier Duval ThemaClassic F 25 E?
Yes, the ThemaClassic F 25 E is confirmed in the list of compatible boilers for this PCB.
What code is printed on this PCB of the ThemaClassic F 25 E?
It reads "SYMS17.0", although one character is uncertain and it could also be read as "SYMSI7.0".
Does this PCB also work for the Thematek C 24 E?
Yes, the Thematek C 24 E is on the list of compatible boilers, along with Isofast, Isotwin, Thema, and Themafast.

Spare parts related to Saunier Duval ThemaClassic

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Main PCB Saunier Duval ThemaClassic F 25 E Ref. S10470