PCB Biasi Myto Condens 24 SIT Ref. BI2035100
The Biasi Manaut Myto Condens 24 SIT PCB, reference BI2035100, is the control unit that manages the ignition, gas valve, and safety functions of the boiler. When this part fails, the user may experience a generic control unit lockout, indicated by the fault code Er 03 / 03E. It is compatible with several models in the Manaut Myto Condens range, such as the Myto Condens 24 and 35, among others. It is recommended to replace it if the mentioned symptoms occur or if the boiler does not operate correctly.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI2035100
PCB with reference BI2035100. Four confirmed compatibilities: Myto Condens 24 and Myto Condens 35.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Myto Condens 24 | Biasi Myto Condens | Contrasted |
| Biasi Myto Condens 35 | Biasi Myto Condens | Contrasted |
| Biasi Myto Condens Inox 24 | Biasi Myto Condens | Contrasted |
| Biasi Myto Condens Inox 35 | Biasi Myto Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. BI2035100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI2035100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB BI2035100 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows nothing on the display.
Cause: The PCB is not supplying power to the other components, usually due to an internal fault or a blown fuse.
First, check that 230V power is reaching the boiler and that the fuse on the PCB is intact.
- 02
The remote control or the panel do not change anything in the boiler.
Cause: The PCB has stopped reading or responding to the temperature and mode commands it receives.
Check that the wiring of the thermostat or the communication bus is properly connected to the terminal block of the PCB.
- 03
An error code appears that does not clear even after resetting the boiler.
Cause: The control detects an internal anomaly and blocks operation as a safety measure.
Note the fault code displayed and compare it with the boiler manual to confirm that it points to the PCB.
- 04
The boiler restarts or blinks intermittently without a clear pattern.
Cause: It is usually due to a fault in a component of the PCB that causes intermittent cuts in the electronics.
Check that the connectors are not loose or corroded before replacing the complete PCB.
Fault codes for Biasi that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| Er 03 / 03E | Generic control board lockout: the control board enters lockout due to an internal fault that does not fit any other specific fault code. | It is the code that the control board itself emits when its internal electronics/logic or the coding connector (which identifies the model to the board) fails; as it is a lockout not associated with a specific sensor, fan, or thermostat, the usual cause is the board itself or its connection. Verify: perform a reset; if it recurs without an external cause, measure/relocate the coding connector and, if it persists, replace the board (BI2035100). |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi BI2035100 PCB.
- Catalogue reference
- BI2035100
- Brand
- Manaut
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Manual Biasi Myto Condens Inox 35 (PDF)Document © Biasi, provided as a technical reference.