PCB Display 7530207_01 - Biasi Advance Plus / Myto Condens / SIT M160
Biasi Advance Plus and Myto Condens incorporate the PCB 7530207_01, which controls the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler may not start, become locked, or exhibit erratic behavior. This PCB is compatible with several models, including Myto Condens 24, Myto Condens 35, Myto Condens Inox 24, and Myto Condens Inox 35, among others. It should be replaced when these fault symptoms are detected.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI2195113
PCB with reference BI2195113. Four confirmed compatibilities: Myto Condens 24 and Myto Condens 35.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Myto Condens 24 | Myto Condens | Contrasted |
| Biasi Myto Condens 35 | Myto Condens | Contrasted |
| Biasi Myto Condens Inox 24 | Myto Condens | Contrasted |
| Biasi Myto Condens Inox 35 | Myto Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. BI2195113 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI2195113. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB BI2195113 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The screen does not turn on or stays black.
Cause: The LCD display is not receiving power or signal from the main PCB, although the boiler can continue to operate.
Check the wiring and connectors between the display and the main PCB before replacing the complete module.
- 02
The buttons on the screen do not respond when pressed.
Cause: The three buttons (SW1, SW2, SW3) are integrated into the display PCB itself; if their contacts fail, the unit does not respond.
Test each button separately; if none respond, suspect the connection cable before the PCB itself.
- 03
The parameters and fault codes cannot be viewed or changed.
Cause: This PCB concentrates all user visualization and interaction, so its failure blocks access to the menu and notifications.
Check if the boiler is still providing heating or domestic hot water normally; this indicates that the problem is with the display and not with the main control.
- 04
The display flickers or turns off and on by itself, without a fixed pattern.
Cause: A bent pin or dirt in the connector of the display PCB can cause intermittent image cuts.
Visually inspect the screen connector for bent pins or corrosion before declaring the PCB defective.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi PCB BI2195113
- Catalogue reference
- BI2195113
- Brand
- Biasi
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Silkscreened code on the PCB
- 7530207_01
- Barcode on label
- 034A0066
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Manual Biasi Myto Condens Inox 35 (PDF)Document © Biasi, provided as a technical reference.