PCB Biasi Micon 24E / Minox
If your boiler does not start, gets blocked, or exhibits erratic behavior, you may need the Biasi Micon 24E / Minox PCB. This part is responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. It is installed in the Micon 24E boiler, among others. Replacing this board is necessary when faults in operation are detected that prevent the proper start of the boiler.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference C320788
PCB with reference C320788. A proven compatibility: Micon 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Micon 24 E | Micon | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. C320788 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference C320788. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB C320788 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not respond to anything: no indicators, no display, it doesn't start for either heating or domestic hot water.
Cause: The PCB is dead and does not distribute power to the rest of the circuit.
Before changing the PCB, measure with a multimeter that 230V is reaching the input and check the fuse on the board itself.
- 02
The burner tries to ignite, you can hear the spark, but the boiler locks out immediately and needs to be reset.
Cause: The microprocessor on the PCB does not receive or interpret the flame signal correctly and shuts down for safety.
Write down the exact fault code displayed on the screen before ruling out the PCB; it might point to the flame sensor, not the electronics.
- 03
The wall control or thermostat is not able to start the boiler, even though it has batteries and appears to be on.
Cause: The PCB has stopped communicating with the thermostat.
Try bypassing the demand directly at the PCB terminals; if it starts this way, the problem is with the thermostat, not the PCB.
- 04
The boiler runs for a while and then stops on its own, without a fixed pattern, and sometimes starts up again by itself.
Cause: A power component of the PCB (relay or triac) degrades with heat and fails intermittently.
Check that fans and pumps rotate freely and do not strain the PCB due to friction before considering it faulty.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi PCB C320788
- Catalogue reference
- C320788
- Brand
- Biasi
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Integrated circuit code
- C321001
- Transformer code
- TS06 / 929
- Without external sources confirming manufacturer, reference, or equivalences.