PCB Bertelli & Partners For Biasi M90.24S / Micon 24 E - Ref. BI1305101
PCB of the boiler manufactured by Bertelli & Partners, with the code 44020AF7377 printed on the circuit and protected by a fuse F3.15A 250V. It is compatible with Biasi boilers M90.24S, M90.28S, M90.32S, M96.24SM/B, M96.28SM/B and with the models Micon 24 E, Minox 24 E, Minox 28 E and Minox 32 E, which share this same PCB.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI1305101
PCB with reference BI1305101. Six confirmed compatibilities: Minox 24 E and Minox 28 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Minox 24 E | Biasi Minox E | Contrasted |
| Biasi Minox 28 E | Biasi Minox E | Contrasted |
| Biasi Minox 32 E | Biasi Minox E | Contrasted |
| Biasi Micon 24 E | Biasi Micon | Contrasted |
| Biasi M90.24 CM/B | Biasi M90 | Contrasted |
| Biasi M90.24S | Biasi M90 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number BI1305101 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1305101. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB BI1305101 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is unresponsive, neither the display lights up nor any indicator.
Cause: The protection fuse of the PCB has blown or the power supply is damaged.
Check if the F3.15A fuse on the PCB is blown before considering that the board is dead.
- 02
The boiler tries to ignite but shuts off without producing a flame.
Cause: The PCB does not manage the ignition correctly and shuts off for safety.
Check the ignition electrode and the flame detection electrode before replacing the PCB.
- 03
The buttons on the panel are not working or the display is frozen.
Cause: The microcontroller on the PCB has frozen or is experiencing an internal fault.
Cut the power to the boiler for one minute and reconnect it; if the problem persists, it is not an intermittent fault.
- 04
Fault codes appear that do not correspond to damaged components.
Cause: The PCB is incorrectly interpreting a signal from a sensor or has a damaged output.
Compare the exact code with the manufacturer's manual and first check the indicated component.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi PCB BI1305101
- Catalogue reference
- BI1305101
- Brand
- Biasi
- Type of part
- PCBs (control boards)
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Bertelli & Partners
- Component code
- 44020AF7377
- Fuse
- F3.15A 250V MAX.