Honeywell PCB 45.006.979-001 REV.A · PLC345 for Ferroli Domina F24

Honeywell PCB 45.006.979-001 REV.A · PLC345 for Ferroli Domina F24

Application for the exact variant pending confirmation. Honeywell control PCB with a power supply of 230 VAC and 50 Hz. It has terminals marked FAN and FLAME and inputs marked H.P. Pressure and L.P. Pressure. Compare its code with that of your PCB before ordering it.

internal SKU
PLC345
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Honeywell compatible boilers

PCB. 0 verified compatibilities. There are another 1 models that we are still checking.

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Honeywell Ferroli Domina F24HoneywellUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the Honeywell marking on the plate "45.006.979-001 REV.A": this is the main code. The unit's bag carries "45,005,979-001": its second block is 005, not 006.
  2. Compare the SCHRACK relay: it should have V23148-B0010-A101 and the marking T7NS5D1-24.
  3. Look at the terminals and inputs marked: FAN, FLAME, H.P. Pressure, and L.P. Pressure.
  4. Do not confuse it with other PCBs for the Domina (39807690, 39804870, 288.92.0006): they are different codes.
  5. if they match, call us at 911 17 77 77 with your boiler model and we will let you know if we have it available.
Technical data

Technical sheet: Honeywell PCB

Uniclima internal SKU
PLC345
Brand
Honeywell
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Power supply PCB
230 VAC
Frequency
50 Hz
Apparent power
4 VA
PCB review
REV. A
PCB material/class
CPC-E 94V-0
SCHRACK relay subcomponent V23148-B0010-A101
18 VDC
SCHRACK T7NS5D1-24 relay marking
10A/5A @ 120VAC; 10A/5A @ 28VDC; VAC COSφ=1; 0610
Terminal/marked function — FAN
fan
Terminal/marked function — FLAME
FLAME
Marked entries
H.P. Pressure and L.P. Pressure
Honeywell PCB marking
45.006.979-001 REV.A
Stock code
45,005,979-001
Identification — Honeywell PCB Marking
45.006.979-001 REV.A
Identification — Code on bag
45,005,979-001
Technical sheet: Power supply PCB
230 VAC
Technical sheet: Frequency
50 Hz
Technical sheet: Apparent power
4 VA
Technical sheet: Material/class PCB
CPC-E 94V-0
Subcomponent technical sheet: SCHRACK V23148-B0010-A101
18 VDC
Marked on relay SCHRACK T7NS5D1-24
10A/5A @ 120VAC; 10A/5A @ 28VDC; VAC COSφ=1; 0610
Bornera/función marcada — FAN
fan
Bornera/función marcada — FLAME
FLAME
Technical sheet: Marked inputs
H.P. Pressure and L.P. Pressure
Registered reference
45.006.979-001
Additional markings
PCB REV. A review; material/class CPC-E 94V-0. Marked Honeywell 45.006.979-001 REV.A. Bag code alternatively transcribed as 45,005,979-001; kept distinct. SCHRACK relay V23148-B0010-A101: 18 VDC. Another relay marking SCHRACK T7NS5D1-24: 10 A / 5 A at 120 VAC and 10 A / 5 A at 28 VDC; VAC COSφ=1; 0610. Terminals/functions: FAN and FLAME. Inputs marked H.P. Pressure and L.P. Pressure.
Pending applications to verify
FERROLI DOMINA F24 — compatibility noted; pending confirmation by variant.
Before purchasing
  • Do not confuse: 39807690 · I39807690 · 36506670 — MF03F.1 PCB (S4562DM1022V01) with Ferroli code 39807690, which at least for the Domina F24, F24 E or F30 E; according to it replaces 36506670, 36506770, 36507000 and 39805900 — It is another code: none of those sheets mention 45.006.979-001. Compare the complete code.
  • Do not confuse: 39804870 · 36506550 — Honeywell S4562 DM 1525 card for Domina F24, F24 E, F30 and F30 E; another describes I39804870 as ignition board S4562DM1006 (F24E) — Another code; they do not match in what it is and none mentions 45.006.979-001.
  • Do not confuse: 288.92.0005 · 288.92.0006 · 288.92.0001 — Ferroli modules for the Domina F24E: MF01 (also C24E, VMC24.E), MF03F.1 (F24 E met and gpl) and MF02 (F24E, F30E) — These are different Ferroli codes; the technical sheet does not mention 45.006.979-001.
  • Do not confuse: 39804831 — Main PCB MF02 for the Domina F24 (the title does not indicate the brand of the PCB) — Another code; the technical sheet does not mention 45.006.979-001.
  • The code of the bag (45,005,979-001) differs by one digit from the one marked on the PCB (45.006.979-001): always compare the one on the PCB.
  • Registered application: the boiler, the codes, and the data from the PCB. None of the readings mention fault code 45.006.979-001; this does not change the registered application.
  • Pending confirmation of registered applications by model, variant, or programming: Ferroli Domina F24.
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

How do I recognize the Honeywell 45.006.979-001 PCB?
Check the label for the marking "45.006.979-001 REV.A" from Honeywell (REV.A is the circuit revision). Also, verify the relay SCHRACK V23148-B0010-A101 (marked T7NS5D1-24) and the terminals FAN and FLAME. PLC345 is the reference from our warehouse.
Is it suitable for my Ferroli Domina F24?
The compatibility of this variant is pending confirmation. Registered application: the PCB 45.006.979-001 REV.A for the Ferroli Domina F24. Compare the marking on your PCB with ours before ordering it: for that boiler, PCBs with other codes (39807690, 39804870, 39804831).
Is it compatible with the Domina F24 E or the Domina F30?
The compatibility of this variant is pending confirmation. We do not take it for granted: registered: the Domina F24. for the F24 E other PCBs (288.92.0005, 288.92.0006, 39807690) and for the F30 E the 39807690 and the MF02 288.92.0001. Send us a photo of your PCB and the boiler's data plate from Contact, or call 911 17 77 77.
Why is the code of the bag (45,005,979-001) not the same as that of the PCB?
The PCB is marked 45.006.979-001 REV.A and the bag is labeled 45.005.979-001: they differ by one digit (006 versus 005). Note both. Always compare the marking on the PCB; we do not have a manufacturer's table explaining the difference.
What other PCBs are compatible with the Domina F24 or F24 E and are not this one?
The most repeated one is the MF03F.1 (S4562DM1022V01), Ferroli code 39807690 (also I39807690 and 36506670): at least for the Domina F24, F24 E or F30 E. Others: 39804870 (S4562 DM 1525), 39804831 (MF02) and the Ferroli modules 288.92.0005 (MF01), 288.92.0006 (MF03F.1) and 288.92.0001 (MF02). None of those sheets mention 45.006.979-001 and we do not claim that they are equivalent: compare the complete code.
Which PCB do the manuals of the Domina F24 E mention?
The technical manual of the Domina F 24-30 E states that the board is a "Honeywell MF03," with a 2 A fuse: part operates at 24 V and the rest at 230 V. The user and installation manual of the Domina F 24 E from Ferroli refers to the board as "MF03F" in the electrical diagram. Neither mentions 45.006.979-001 in the excerpts read: compare the code of your board.
Can I install it myself?
It is not recommended. The PCB operates at 230 VAC in a gas boiler, so it should be installed by a qualified technician, with the boiler disconnected from the power supply.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell PCB 45.006.979-001 REV.A · PLC345 for Ferroli Domina F24