Honeywell PCB 45.007.000-002 for Ferroli New Elite F24 E
Application for the exact variant pending confirmation. PCB with LCD screen and buttons for boiler. In New Elite F 24 E, a persistent fault may require checking the main board; it remains to identify its reference and its correspondence with this unit.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC346
- Warranty
- 1 year
Honeywell compatible boilers
PCB. 0 verified compatibilities. There are another 1 models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Honeywell Ferroli New Elite F24 E | Honeywell | Unconfirmed |
|---|
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the marking "Honeywell 45.007.000-002" and the revision REV.A on the PCB.
- Compare the blue subcomponent: it has DSP49, A1001, and 0311, with PASS marked separately.
- Check that your PCB has an LCD screen and buttons, like ours.
- Do not confuse it with the 45.007.000-003 REV.B, the CENTRAL KIT 39809822, or the reference DSP49A / I39809641 that some refer to as display: they are different codes.
- if they match, call us at 911 17 77 77 with the model of your boiler. Any questions? Send us a photo of the label of your part and the data plate of the boiler from Contact.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The problem persists.
Cause: The official manual for the New Elite F 24 E (Troubleshooting) states: "If the problem persists, check the main PCB and replace it if necessary." It does not assign the fault to an F code nor does it identify the PCB by code: it does not test whether this is the board.
- 02
The boiler locks with F8 after ignition, without flame.
Cause: Anomaly of the card or disturbances in the network.
Check the grounding. If the fault recurs, have a technician inspect or replace the PCB.
- 03
The boiler locks with F10 + F22 or with F25 and fails again after resetting it.
Cause: Fault of the microprocessor or the software of the main PCB.
Cut off and reset the power. If the issue persists, have a technician check or replace the main PCB.
- 04
The boiler is locking with fault code F36.
Cause: Fault in the PCB.
Have a technician replace the PCB.
- 05
The boiler locks with F30, F31, F32, or F33 (sensor warnings).
Cause: Faulty sensor, or interrupted or short-circuited wiring.
Check the wiring of the sensor. If it is fine, have a technician replace the sensor.
Honeywell fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F1 | The burner does not ignite. Checked on New Elite F 24 E and F 30 E. | Before checking the PCB, inspect the electrodes, ignition wiring, and gas valve. Only point to the PCB if those parts are fine; have a technician check it. |
| F8 | There is no flame after the ignition phase. Verified on New Elite F 24 E and F 30 E. | Check the grounding and ensure that the electrical network is free of disturbances. If the warning repeats, it points to the PCB; have a technician check it. |
| F9 | There is no communication between the electronic unit and the gas valve. Verified on New Elite F 24 E and F 30 E. | Check the wiring between the PCB and the gas valve. If the wiring is fine, it points to the PCB or the valve; have a technician check it. |
| F10 + F22 | Microprocessor anomaly of the PCB. Verified in New Elite F 24 E and F 30 E. | Cut the power for a moment and reconnect it. If it appears again, point to the main board; have a technician check it. |
| F25 | Software anomaly of the PCB. Verified in New Elite F 24 E and F 30 E. | Cut the power for a moment and reconnect it. If the issue persists, point to the main PCB; have a technician check it. |
| F30 | Return sensor anomaly: faulty sensor or short circuit. Verified on New Elite F 24 E and F 30 E. | Check the wiring of the sensor. Point to the PCB only if the sensor and its wiring are fine; have a technician check it. |
| F31 | Return sensor anomaly: faulty sensor or interrupted wiring. Verified on New Elite F 24 E and F 30 E. | Check the wiring of the sensor. Point to the PCB only if the sensor and its wiring are fine; have a technician check it. |
| F32 | Domestic hot water sensor anomaly: faulty or short-circuited sensor. Verified in New Elite F 24 E and F 30 E. | Check the wiring of the sensor. Point to the PCB only if the sensor and its wiring are fine; have a technician check it. |
| F36 | Anomaly in the electronic PCB. Verified in New Elite F 24 E and F 30 E. | Indicate fault of the PCB. Have a technician replace it. |
| F37 | Heating water pressure too low. Checked on New Elite F 24 E and F 30 E. | Check the pressure of the installation. If it is correct and the warning persists, it points to the pressure sensor; have a technician check it. |
| F39 | Anomaly of the external sensor: sensor damaged or short-circuited. Verified in New Elite F 24 E and F 30 E. | It only appears if an external sensor is installed. Check its wiring; if it is fine, replace the sensor. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Honeywell PCB
- Uniclima internal SKU
- PLC346
- Brand
- Honeywell
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Review
- A
- PCB marking
- Honeywell 45.007.000-002
- Blue subcomponent
- DSP49; A1001; 0311; marked separated PASS
- Visible interface
- LCD screen and buttons
- PCB marking
- REV.A
- Identification — Marked code
- 45.007.000-002
- Identification — Marked code
- REV.A
- Technical sheet: Review
- A
- Technical sheet: PCB marking
- Honeywell 45.007.000-002
- Subcomponent blue
- DSP49; A1001; 0311; marked separated PASS
- Visible interface
- LCD screen and buttons
- Technical sheet: Marked PCB
- REV.A
- Additional markings
- PCB REV.A; marked Honeywell 45.007.000-002. Blue subcomponent: DSP49; A1001; 0311; marked PASS separately. Interface: LCD screen and buttons.
- Pending applications to verify
- Ferroli New Elite F24 E — compatibility noted; pending confirmation by variant.
- Do not confuse: 45.007.000-003 — Ferroli PCB "REV.B" (electronic version 45.007.018-003 REV.B), — Another code and another revision (-003 REV.B compared to -002 REV.A); without additional confirmation, it links to this PCB.
- Do not confuse: 39809822 — KIT CENTRAL.DCF01.2 (36507392) from the New Elite F24E, position 1D16 of the official spare parts list from Ferroli; it is sold as an ignition board — The official list does not have any line with 45.007.000-002: it is not stated that this is the PCB.
- Do not confuse: 39809641 · I39809641 · DSP49A — DISPLAY BOARD KIT 39809641 in the official list of the F24E. I39809641 / DSP49A for the New Elite and there is no agreement on what it is: it lists it as display board DSP49A and as display DSP49A (without that code); it lists it as the main control board of the F24E and the table as "PCB (control board)", although it indicates that the display is on the front — Another code. Your board has an LCD screen and a subcomponent DSP49, but Unconfirmed: the 45.007.000-002 for that board.
- Do not confuse: I39817770 — PMF09F board from the New Elite 60 F24, according to its parts list — Another boiler model and another code; it is not stated that this is the PCB.
- All are marked as read on the part itself. We have not found 45.007.000-002 in the spare parts lists that we were able to read. The official Ferroli spare parts portal could not be opened.
- Compatibility with the Ferroli New Elite F24 E registered. Without additional external confirmation, nor the official spare parts list of the F24E, it still includes the code 45.007.000-002.
- Pending confirmation of registered applications by model, variant, or programming: Ferroli New Elite F24 E.