Application for the exact variant pending confirmation. PCB with LCD screen and buttons for boiler. In New Elite F 24 E, a persistent fault may require checking the main board; it remains to identify its reference and its correspondence with this unit.

internal SKU
PLC346
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Honeywell compatible boilers

PCB. 0 verified compatibilities. There are another 1 models that we are still checking.

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Honeywell Ferroli New Elite F24 EHoneywellUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the marking "Honeywell 45.007.000-002" and the revision REV.A on the PCB.
  2. Compare the blue subcomponent: it has DSP49, A1001, and 0311, with PASS marked separately.
  3. Check that your PCB has an LCD screen and buttons, like ours.
  4. Do not confuse it with the 45.007.000-003 REV.B, the CENTRAL KIT 39809822, or the reference DSP49A / I39809641 that some refer to as display: they are different codes.
  5. if they match, call us at 911 17 77 77 with the model of your boiler. Any questions? Send us a photo of the label of your part and the data plate of the boiler from Contact.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The problem persists.

    Cause: The official manual for the New Elite F 24 E (Troubleshooting) states: "If the problem persists, check the main PCB and replace it if necessary." It does not assign the fault to an F code nor does it identify the PCB by code: it does not test whether this is the board.

  • 02

    The boiler locks with F8 after ignition, without flame.

    Cause: Anomaly of the card or disturbances in the network.

    Check the grounding. If the fault recurs, have a technician inspect or replace the PCB.

  • 03

    The boiler locks with F10 + F22 or with F25 and fails again after resetting it.

    Cause: Fault of the microprocessor or the software of the main PCB.

    Cut off and reset the power. If the issue persists, have a technician check or replace the main PCB.

  • 04

    The boiler is locking with fault code F36.

    Cause: Fault in the PCB.

    Have a technician replace the PCB.

  • 05

    The boiler locks with F30, F31, F32, or F33 (sensor warnings).

    Cause: Faulty sensor, or interrupted or short-circuited wiring.

    Check the wiring of the sensor. If it is fine, have a technician replace the sensor.

Honeywell fault codes that require diagnosis

CodeFaultTechnical checks
F1The burner does not ignite. Checked on New Elite F 24 E and F 30 E.Before checking the PCB, inspect the electrodes, ignition wiring, and gas valve. Only point to the PCB if those parts are fine; have a technician check it.
F8There is no flame after the ignition phase. Verified on New Elite F 24 E and F 30 E.Check the grounding and ensure that the electrical network is free of disturbances. If the warning repeats, it points to the PCB; have a technician check it.
F9There is no communication between the electronic unit and the gas valve. Verified on New Elite F 24 E and F 30 E.Check the wiring between the PCB and the gas valve. If the wiring is fine, it points to the PCB or the valve; have a technician check it.
F10 + F22Microprocessor anomaly of the PCB. Verified in New Elite F 24 E and F 30 E.Cut the power for a moment and reconnect it. If it appears again, point to the main board; have a technician check it.
F25Software anomaly of the PCB. Verified in New Elite F 24 E and F 30 E.Cut the power for a moment and reconnect it. If the issue persists, point to the main PCB; have a technician check it.
F30Return sensor anomaly: faulty sensor or short circuit. Verified on New Elite F 24 E and F 30 E.Check the wiring of the sensor. Point to the PCB only if the sensor and its wiring are fine; have a technician check it.
F31Return sensor anomaly: faulty sensor or interrupted wiring. Verified on New Elite F 24 E and F 30 E.Check the wiring of the sensor. Point to the PCB only if the sensor and its wiring are fine; have a technician check it.
F32Domestic hot water sensor anomaly: faulty or short-circuited sensor. Verified in New Elite F 24 E and F 30 E.Check the wiring of the sensor. Point to the PCB only if the sensor and its wiring are fine; have a technician check it.
F36Anomaly in the electronic PCB. Verified in New Elite F 24 E and F 30 E.Indicate fault of the PCB. Have a technician replace it.
F37Heating water pressure too low. Checked on New Elite F 24 E and F 30 E.Check the pressure of the installation. If it is correct and the warning persists, it points to the pressure sensor; have a technician check it.
F39Anomaly of the external sensor: sensor damaged or short-circuited. Verified in New Elite F 24 E and F 30 E.It only appears if an external sensor is installed. Check its wiring; if it is fine, replace the sensor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Honeywell PCB

Uniclima internal SKU
PLC346
Brand
Honeywell
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Review
A
PCB marking
Honeywell 45.007.000-002
Blue subcomponent
DSP49; A1001; 0311; marked separated PASS
Visible interface
LCD screen and buttons
PCB marking
REV.A
Identification — Marked code
45.007.000-002
Identification — Marked code
REV.A
Technical sheet: Review
A
Technical sheet: PCB marking
Honeywell 45.007.000-002
Subcomponent blue
DSP49; A1001; 0311; marked separated PASS
Visible interface
LCD screen and buttons
Technical sheet: Marked PCB
REV.A
Additional markings
PCB REV.A; marked Honeywell 45.007.000-002. Blue subcomponent: DSP49; A1001; 0311; marked PASS separately. Interface: LCD screen and buttons.
Pending applications to verify
Ferroli New Elite F24 E — compatibility noted; pending confirmation by variant.
Before purchasing
  • Do not confuse: 45.007.000-003 — Ferroli PCB "REV.B" (electronic version 45.007.018-003 REV.B), — Another code and another revision (-003 REV.B compared to -002 REV.A); without additional confirmation, it links to this PCB.
  • Do not confuse: 39809822 — KIT CENTRAL.DCF01.2 (36507392) from the New Elite F24E, position 1D16 of the official spare parts list from Ferroli; it is sold as an ignition board — The official list does not have any line with 45.007.000-002: it is not stated that this is the PCB.
  • Do not confuse: 39809641 · I39809641 · DSP49A — DISPLAY BOARD KIT 39809641 in the official list of the F24E. I39809641 / DSP49A for the New Elite and there is no agreement on what it is: it lists it as display board DSP49A and as display DSP49A (without that code); it lists it as the main control board of the F24E and the table as "PCB (control board)", although it indicates that the display is on the front — Another code. Your board has an LCD screen and a subcomponent DSP49, but Unconfirmed: the 45.007.000-002 for that board.
  • Do not confuse: I39817770 — PMF09F board from the New Elite 60 F24, according to its parts list — Another boiler model and another code; it is not stated that this is the PCB.
  • All are marked as read on the part itself. We have not found 45.007.000-002 in the spare parts lists that we were able to read. The official Ferroli spare parts portal could not be opened.
  • Compatibility with the Ferroli New Elite F24 E registered. Without additional external confirmation, nor the official spare parts list of the F24E, it still includes the code 45.007.000-002.
  • Pending confirmation of registered applications by model, variant, or programming: Ferroli New Elite F24 E.
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

What is the Honeywell 45.007.000-002 PCB and how do I identify it?
It is a PCB marked "Honeywell 45.007.000-002" (circuit code, PCB) and revision REV.A. It has an LCD screen and buttons, and a blue subcomponent marked DSP49, A1001, and 0311, with PASS separately. There is disagreement regarding DSP49A: two sources list it as the display card for the New Elite and one as a PCB or control unit; none link it to this board. No documentation mentions A1001 or the marking 0311 of the blue subcomponent; 0311 only appears within the code 38320311 of the official DISPLAY BOARD KIT list.
Is it compatible with my Ferroli New Elite F24 E?
The compatibility of this variant is pending confirmation. Registered application: this PCB for the Ferroli New Elite F24 E. The official parts list for the New Elite F24E (code 30K0278000) that we have reviewed does not include the code 45.007.000-002, so we cannot provide you with a Ferroli catalog reference: compare the markings on the part with those on your PCB.
And what if my boiler is not the New Elite F24 E?
The compatibility of this variant is pending confirmation. To be confirmed: For other boilers, we do not have confirmation from the workshop nor that this code is associated with them. I39809641 / DSP49A for New Elite F24, F30, C24, and C30, and a third one DSP49A only for New Elite F24E and F30E; it is a different code and we do not extend the 45.007.000-002 to those boilers. Send us a photo of your PCB from Contact or call 911 17 77 77.
Is it the same as the Ferroli 45.007.000-003 REV.B PCB?
We don't know. The Ferroli PCB 45.007.000-003 REV.B (electronic version 45.007.018-003 REV.B), but it does not link to the 45.007.000-002. This PCB is -002 and REV.A: compare the complete code and the revision, and do not consider it equivalent.
Is it the same as the CENTRAL KIT 39809822 or the reference DSP49A / I39809641 from the New Elite?
We don't know. The official parts list for the New Elite F24E includes the KIT CENTRAL.DCF01.2 with code 39809822, as well as the KIT SCHEDA DISPLAY 39809641. DSP49A / I39809641, and there is no agreement on what it is: some refer to it as a display card and others as a control board or central unit. Your board has an LCD screen and a subcomponent marked DSP49, but it is not confirmed: the 45.007.000-002 with those codes. We do not consider it equivalent.
How do I know if the fault of my New Elite F24 E comes from this PCB?
A fault code alone does not prove it. The official manual for the New Elite F 24 E (Troubleshooting) states: "If the problem persists, check the main PCB and replace it if necessary." It does not assign that cause to an F code nor identify the PCB by code. Have a technician diagnose it before purchasing.
Who should install this PCB?
A qualified technician. It is a PCB of a boiler, connected to the electrical network. Before touching anything, the power supply must be cut off and the gas closed.