Fondital Minorca KC24 Nordgas PCB Ref. 6SCHEMOD35

Fondital Minorca KC24 Nordgas PCB Ref. 6SCHEMOD35

The PCB 6SCHEMOD35 (Nordgas) is the modulation board for the condensation boilers Fondital Minorca KC24, KR, and KRB, as well as Nova Florida Nibir KC, KR, and KRB. The 6SCHEMOD50 is its subsequent code. It is sold refurbished, tested, and with a 1-year warranty.

internal SKU
PLC436
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Fondital boilers compatible

PCB. Six confirmed compatibilities: Minorca KC24 and Minorca KR.

Proven compatibility

Boiler modelFamilyVerification
Fondital Minorca KC24FonditalContrasted
Fondital Minorca KRFonditalContrasted
Fondital Minorca KRBFonditalContrasted
Fondital Nibir KCNova FloridaContrasted
Fondital Nibir KRNova FloridaContrasted
Fondital Nibir KRBNova FloridaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Check the Nordgas logo on the circuit.
  2. Compare the reference. The reference is 6SCHEMOD35; the 6SCHEMOD50 is the subsequent code. If yours is a 6SCHEMOD50, please consult us before ordering it.
  3. Look at the model on the boiler's rating plate: Minorca KC24, KR or KRB, Nibir KC, KR or KRB.
  4. Discard other PCBs: it is not the 6CIRCSTA21 (Minorca-Nibir interconnection) nor the 6SCHEMOD19 from another series of boilers.
  5. Compare the fuse: the PCB has 3.15 A F. If you have doubts about your model, call us at 911 17 77 77 with the complete model of your boiler.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The burner does not ignite and the boiler shows E01.

    Cause: In the Minorca and Nibir KC-KR-KRB, the indicated cause for E01 is the faulty PCB.

    The replacement is carried out by qualified personnel. E01 does not identify the reference of the PCB: please consult us before ordering it.

  • 02

    The burner ignites for a few seconds and then turns off.

    Cause: In the Minorca KC-KR-KRB, the board does not detect the flame because the phase and neutral are inverted. The cause lies in the electrical connection, not in the PCB.

    Check that the phase-neutral connection to the electrical network is correct. If it was reversed, correct it before considering changing the PCB.

Fault codes Fondital that require diagnosis

CodeFaultTechnical checks
E01The burner does not igniteThe indicated cause in the Minorca and Nibir KC-KR-KRB is the faulty PCB. It must be replaced by qualified personnel. E01 alone is not enough to decide on the replacement: consult us before ordering it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Fondital PCB

Uniclima internal SKU
PLC436
Brand
Fondital
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Reference
6SCHEMOD35
Subsequent code
6SCHEMOD50 (previously 6SCHEMOD35)
Part
Condensing modulation PCB
Denomination in Italian
Condensing modulation board
PCB manufacturer
Nordgas
Boiler brands
Fondital and Nova Florida
Firmware
H047D (Fw:H047D)
PCB fuse
3.15 A F
Connection
Green terminal block with 4 screws (M0904)
Units per boiler
1
Status
Refurbished and tested, with a 1-year warranty.
Before purchasing
  • Do not confuse with 6CIRCSTA21: Interconnection PCB for the Minorca and Nibir. It is a different board, not the modulation one.
  • Do not confuse with 6SCHEMOD19: Modulation PCB from another series of Fondital boilers.
  • Please consult us before purchasing if your boiler is: Fondital Leo KC, Fondital Tenerife KC.
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

Is it compatible with my Fondital Minorca or Nova Florida Nibir?
Yes, if it is a Minorca KC24, KR or KRB, or a Nibir KC, KR or KRB. It is the modulation PCB for that family. If your model is not in the sheet, call us at 911 17 77 77 with the full model.
What is the difference between the 6SCHEMOD35 and the 6SCHEMOD50?
The 6SCHEMOD50 is the later code of the 6SCHEMOD35. If your PCB has the code 6SCHEMOD50, call us at 911 17 77 77 with the model of your boiler.
Does it also fit in the Fondital Leo KC and Tenerife KC?
Contact us with the full model of your boiler and the marking on your PCB. Call us at 911 17 77 77.
What does error E01 indicate in a Minorca or a Nibir?
E01 indicates that the burner does not ignite. The indicated cause is a faulty PCB. E01 does not identify the reference of the board, so it is not enough to decide on the replacement. Confirm the marking on yours before ordering.
Can it be confused with other PCBs from Fondital?
Yes. The 6CIRCSTA21 is the interconnection PCB for the Minorca and Nibir, not the modulation one. The 6SCHEMOD19 is the modulation PCB for another series of Fondital boilers.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Fondital Minorca KC24 Nordgas PCB Ref. 6SCHEMOD35