Roca Victoria FF PCB · 1271002110 · 9555507400 (12736-01A)
Aplicación a la variante exacta pendiente de confirmar. Por confirmar: Es la placa electrónica de control de la caldera mural Roca Victoria. relaciona su fallo con calderas que no encienden, no arrancan, se bloquean o funcionan de forma intermitente, aunque esos síntomas pueden tener otras causas.
- Type of part
- Baxi Roca
- Status
- Refurbished
- internal SKU
- PLC142
- Warranty
- 1 year
Compatible Baxi Roca boilers
Roca. 0 compatibilidades contrastadas. Hay otros 10 modelos que todavía estamos comprobando.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Baxi Roca Victoria 20/20 F | Baxi Roca | Unconfirmed |
|---|---|---|
| Baxi Roca Victoria 20/20 T | Baxi Roca | Unconfirmed |
| Roca Victoria 20-20 | Baxi Roca | Unconfirmed |
| Baxi Roca Victoria 24/24 F | Baxi Roca | Unconfirmed |
| Baxi Roca Victoria 28/28 F | Baxi Roca | Unconfirmed |
| Baxi Roca Neobit | Baxi Roca | Unconfirmed |
| Roca Victoria FF | Baxi Roca | Unconfirmed |
| Baxi Roca Victoria Fr | Baxi Roca | Unconfirmed |
| Baxi Roca Victoria II | Baxi Roca | Unconfirmed |
| Baxi Roca Victoria | Baxi Roca | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Busca en tu placa los marcados 1271002110 y 9555507400: usan uno u otro para la placa Roca Victoria.
- Also look at the designation 12736-01A, the protection "3.15A F1" and the terminals GND, +VCC, L, N and TA.
- Check the suffix: other technical sheets show 12736-03A or 12736-04A with the same 1271002110. If yours is not 01A, send us a photo.
- No la confundas con la 122126440, que para la Victoria 20/20 F: no consta que sea la misma placa.
- coinciden, llámanos al 911 17 77 77 con el modelo de tu caldera y te la reservamos.
Symptoms that require diagnosis in the Baxi Roca
Common symptoms and faults
- 01
The boiler does not ignite, does not start, gets blocked, or operates intermittently.
Cause: lo relaciona con la placa 1271002110 (texto de venta). Antes, revisa la alimentación y la protección «3.15A F1» de la placa.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Baxi Roca
- Uniclima internal SKU
- PLC142
- Brand
- Baxi Roca
- Type of part
- Baxi Roca
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Protection screen printing
- 3.15A F1
- Terminal silkscreen
- GND; +VCC; L; N; TA
- Inventory — Application indicated in inventory
- MODEL 1 (12736-01A) VICTORIA Fr VICTORIA II
- Inventory — FT HAA012V Relays
- 12 V DC coil; contacts 10 A 250 VAC and 10 A 30 V DC
- Inventory — Relays
- 12 VDC coil; contacts 10 A 250 VAC~ and 10 A 125 VAC~
- Inventory — Marked code
- 1271002110; VICTORIA FF; 0120; 14588; 9555507400; MTL2; 0114
- Identification — Marked designation
- 12736-01A
- Identification — Marked code
- 1271002110; VICTORIA FF; 0120; 14588
- Identification — Marked code
- 9555507400; MTL2; 0114
- Identification — Marked code
- H1AA012V
- Technical sheet: Protection screen printing
- 3.15A F1
- Technical sheet: Terminal screen printing
- GND; +VCC; L; N; TA
- Inventory data — Application indicated in inventory
- MODEL 1 (12736-01A)
- Inventory data — Relays FT HAA012V
- 12 V DC coil; contacts 10 A 250 VAC and 10 A 30 V DC
- Inventory data — Relays
- 12 VDC coil; contacts 10 A 250 VAC~ and 10 A 125 VAC~
- Inventory data — Application indicated in inventory
- VICTORIA Fr
- Inventory data — Application indicated in inventory
- VICTORIA II
- Inventory data — Marked code
- 1271002110; VICTORIA FF; 0120; 14588; 9555507400; MTL2; 0114
- Pending applications to verify
- VICTORIA FF; VICTORIA FF modelo 1 (12736-01A); VICTORIA Fr; VICTORIA II; VICTORIA — compatibilidades citadas; pendientes de confirmar por variante.
- The symptoms come from a sales text, not from the manufacturer, and no official fault code table for this PCB has been read.
- Por confirmar: Roca Victoria 20/20 F: (1271002110) y (9555507400)
- Por confirmar: Roca Victoria 20/20 T: (1271002110)
- Por confirmar: Roca Victoria 20-20: y (9555507400)
- Por confirmar: Roca Victoria 24/24 F: (9555507400)
- Por confirmar: Roca Victoria 28/28 F: (9555507400)
- Por confirmar: Roca Neobit: (9555507400)
- No confundir: 122126440 — Módulo, tarjeta o cuadro de control que para la Victoria 20/20 F, 20/20 T y FT — Ninguna de esas fichas cita 1271002110 ni 9555507400: no consta que sea la misma placa.
- No confundir: 12736-03A / 12736-04A — Designaciones que otras fichas muestran con 1271002110 para la Victoria FF — La nuestra marca 12736-01A; sin confirmación adicional explica la diferencia.
- Unconfirmed: 12736-01A; otras fichas muestran 12736-03A y 12736-04A con el mismo 1271002110.
- Los códigos 1271002110 y 9555507400 los une a la placa Roca Victoria. Ninguno cita 12736-01A. Catálogo oficial de Baxi bloqueado; los documentación no citan estos códigos.
- Aplicaciones registradas pendientes de confirmar por modelo, variante o programación: Roca Victoria FF; Roca Victoria Fr; Roca Victoria II; Roca Victoria.