Saunier Duval PCB Security STY 300 / STY 150 Ref. A0300018 (030-0018)
The control PCB Saunier Duval Security STY 300 / STY 150 Ref. 030-0018 manages the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, lock out, or behave erratically. It is compatible with the Duval Security STY 150 and STY 300 models. It is recommended to replace it when these symptoms are detected, as a malfunction can affect the performance of your heating system.
VAT included
Consult via WhatsAppCompatible Saunier Duval boilers
PCB. Two confirmed compatibilities: Duval Security STY 150 and Duval Security STY 300.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Duval Security STY 150 | Saunier | Contrasted |
| Saunier Duval Duval Security STY 300 | Saunier | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there are no active indicator lights.
Cause: The PCB manages the overall power supply of the equipment; if the input fails, no current reaches any circuit.
Check the fuse on the PCB and the 5x20 mm fuse holder that it has integrated; it is usually the first thing to burn out if there is a voltage spike.
- 02
It skips a fault code or a fault indicator as soon as you try to turn it on.
Cause: The PCB interrupts the process when it detects an anomaly in flame, pressure, or temperature to protect the boiler.
Check the pressure of the circuit and ensure that the flue is not blocked before attributing it to the PCB.
- 03
The room thermostat is unable to start the boiler even though it is calling for heat.
Cause: The mains coil and the input stage of the PCB filter the power supply; if they fail, the board does not process the thermostat demand.
Check the wiring of the thermostat on the terminal block of the PCB before replacing it.
- 04
The boiler stops by itself during operation, without prior warning.
Cause: A specific fault in the electronics can interrupt the ignition or the gas supply even if the other components are functioning properly.
Note if it always occurs at the same point in the cycle before changing the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval PCB data sheet
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Code printed on PCB
- 030-0018
- Network inductor
- Wurth Elektronik (WE), code 7446621007, 6.8 mH, 1 A, batch 0513
- Fuse