Saunier Duval SYMSI7.0 board · PCB 0310144400R18 for Themafast C25 E and Themaclassic F25E

Saunier Duval SYMSI7.0 board · PCB 0310144400R18 for Themafast C25 E and Themaclassic F25E

It is the PCB of the boiler where the Omron relays and the connection terminals (ALIM 230 V; TA, marked at 230 V on two of our units) are mounted.

Type of part
Saunier Duval
internal SKU
PLC104
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Compatible Saunier Duval boilers

Saunier Duval. Nine confirmed compatibilities: Saunier Duval Themafast F25 E H-MOD and Saunier Duval Thema C24 E V. There are 3 other models that we are still verifying.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast F25 E H-MODSaunier DuvalContrasted
Saunier Duval Thema C24 E VSaunier DuvalContrasted
Saunier Duval Thema Classic C25 ESaunier DuvalContrasted
Saunier Duval Themaclassic F25ESaunier DuvalContrasted
Saunier Duval Themaclassic F 24 ESaunier DuvalContrasted
Saunier Duval Themaclassic C 24 ESaunier DuvalContrasted
Saunier Duval Thema C 25 ESaunier DuvalContrasted
Saunier Duval Thema F 24 E and F 25 ESaunier DuvalContrasted
Saunier Duval Isotwin F 24 ESaunier DuvalContrasted

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Saunier Duval Themafast C 24 E and C 30 ESaunier DuvalUnconfirmed
Saunier Duval Themaclassic F AS 30 E and Thematek S F 24 ESaunier DuvalUnconfirmed
Saunier Duval Themafast C25 ESaunier DuvalUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look at the label for model SYMSI7.0, circuit code 0310144400R18, and manufacturer SUNG WEI 06V0-A.
  2. There is a number that starts with 0020 and changes according to the unit; in one of our units, it is located under the barcode (0020021121 00110 7459). It is not a unique criterion.
  3. Check the transformer, the Omron relays, and the ALIM 230 V, V3V, and P1/P2 terminals. Two of our units show TA 230 V; the Themafast manual states 24 V (never 230 V) at the thermostat connector of the range: check the TA terminal before connecting.
  4. Don't rely solely on S1047000: for many Thema boilers. Compare the complete circuit code.
  5. If they match, call us at 911 17 77 77 with the model of your boiler.
Diagnosis and fault codes

Symptoms that require diagnosis in the Saunier Duval.

Common symptoms and faults

  • 01

    The boiler does not ignite: the fault code F28 appears (ignition fault).

    Cause: Failed ignition: it could be gas, ignition, electrode, or PCB.

    Have a technician check it.

  • 02

    The boiler shuts down during operation and does not restart (fault code F29).

    Cause: Gas cut-off, flue gas recirculation, condensates, or faulty grounding.

    Have a technician check it.

  • 03

    The boiler does not ignite or turns off during operation and does not ignite again (fault codes F28 or F29).

    Cause: Ignition fault: it may be due to lack of gas, gas meter, ignition or PCB.

    Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have it checked by the official SAT.

  • 04

    The boiler does not ignite when starting and fault code F.28 appears.

    Cause: Insufficient gas, condensate siphon blocked or failed ignition.

    Have a technician check the gas, the siphon, and the electrode. Do not touch the gas valve.

  • 05

    The flame goes out during operation and the boiler tries to ignite several times.

    Cause: Dirty ionization electrode, flue gas recirculation or gas cut-off.

    Have a technician check the electrode, the flue gases, and the gas supply.

  • 06

    Fault codes F.00, F.01, F.10 or F.11 appear on the screen.

    Cause: Loose sensor connector, interrupted wiring harness, or faulty NTC sensor.

    Have a technician check the connectors first and then the sensor.

  • 07

    The red pilot light is flashing and a fault code F followed by a number appears on the screen: the boiler stops due to an anomaly.

    Cause: The PCB has detected an anomaly. The number indicates which one: ignition, flue, sensors, or circulation.

    Reset it: turn off the boiler, wait 5 seconds, and turn it back on. If the fault persists, have it checked by the official technical service.

  • 08

    The boiler does not ignite the burner, with the fault code F.28.

    Cause: Gas, electrodes, gas pressure or polarity.

    Have a technician check it. Do not attempt to touch the gas valve.

  • 09

    The boiler detects flame with the burner off: warning F.27.

    Cause: Moisture on the electrode, or gas valve that does not close.

    It is a security fault. Have a technician check it immediately.

  • 10

    The boiler is locking out with the fault code F.61, related to the gas valve.

    Cause: Fault in the gas valve control.

    Have a technician check it: it may be necessary to replace the PCB.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F00Return temperature sensor (NTC2) disconnected.Check if the sensor connector is loose. If it persists, have a technician check it: it could be the sensor, the cable, or the PCB.
F01Return temperature sensor (NTC5) disconnected.Just like the F00: check the connector and, if it persists, have a technician check it.
F27Flame detection fault: the flame control is not reliable.If it occurs when turning on or off, have a technician check it: it could be moisture in the electronics or the flame control.
F28Ignition fault: the burner does not ignite.If it repeats, have a technician check it: it could be the gas, the ignition, or the PCB.
F29Flame loss during operation.If it repeats, have a technician check it: it could be a gas cut-off, flue gas recirculation, or a faulty ground connection.
F61Gas valve activation fault.Have a technician check it: it could be the wiring of the gas valve, its coils, or the electronics.
F62The gas valve does not close in time after the flame goes out.Have a technician check it: the gas valve or the PCB are the suspects.
F15Flame detection fault: there is a flame with the burner off.If it occurs when turning off or on, have a technician check it: it points to the PCB or the flame control.
F5Fault of the heating flow sensor (NTC2).Check if the sensor connector is loose. If it persists, have a technician check it: it could be the sensor, the cable, or the PCB.
F1Ignition fault, possible gas supply issue (in Themafast C; in NOx it appears as F28 or F29).Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have a technician check it.
F.10Short circuit in the supply temperature sensor (inlet).Have a technician check the sensor and the wiring harness. Only point to the PCB if the sensor and wiring are fine.
F.11Short circuit in the return temperature sensor.Have a technician check the sensor and the wiring harness. Only point to the PCB if the sensor and wiring are fine.
F.20Safety disconnection due to overheating.Do not reset it over and over again. Have a technician check it. If the warning returns, it may be due to a lack of water circulation, not the PCB.
F.49Fault in eBUS communication: lack of voltage or short circuit in the line.Check the wiring of the thermostat or the bus. If the warning returns, have a technician check it. Point to the communication PCB.
F.63Fault in the memory (EEPROM) of the PCB.Have a technician check it. The PCB may need to be replaced.
F.65Temperature of the electronics too high.Have a technician check it. Review the location and ventilation of the boiler. Point to the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval

Uniclima internal SKU
PLC104
Brand
Saunier Duval
Type of part
Saunier Duval
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Silkscreened model of PCB
SYMSI7.0
Power supply terminal marking
230 V
Fuse marking/terminal
T1A
Relay subcomponent
Omron G5Q-1A4; 24 V DC
Transformer subcomponent
M24744-E; ZM; 1609
Connector/substrate marking
SUNG WEI 06V0-A
Manufacturing label
KWD; IND 48; S0092
Source of additional data
Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
Inventory — Type
PCB (control board) / boiler control board
Inventory — Transformer subcomponent
M24744-3E; ZM; 1609
Inventory — Marked feeding
ALIM230V
Inventory — Markings close to connections
230V;1A
Inventory — Marked code
0020021125 00081 2784; 09/34;KWD;IND48;S0092
Function of the PCB
Ignition, modulation, domestic hot water temperature and heating temperature, gas safety devices.
Pending applications to verify
Saunier Duval THEMAFAST C25 E — compatibility mentioned; pending verification by variant.
Before purchasing
  • To confirm: Saunier Duval Themafast C 24 E and C 30 E: (R18) and (SYMSI7.0)
  • To confirm: Saunier Duval Themaclassic F AS 30 E and Thematek S F 24 E: (R18)
  • Do not confuse: 0310144400S19 — Circuit that goes along with S1047000 and SYMSI7.0 — Our PCB has 0310144400R18: compare the complete code.
  • To confirm: is SYMSI7.0 written as SYMS17.0 (likely a typo)?
  • for 0310144400R18, 4 for SYMSI7.0. it gives 0310144400S19 as assembly of S1047000/SYMSI7.0; the R18 from the workshop prevails. The Themafast manual provides 24 V to the thermostat connector (without mentioning the PCB); two of our units show TA 230 V: check the terminal.
  • Pending registered applications to confirm by model, variant, or programming: Saunier Duval Themafast C25 E.
Frequently Asked Questions

Frequently asked questions: Saunier Duval

Where is the code for this PCB and what should I compare?
On the PCB, the model SYMSI7.0, the circuit code 0310144400R18, and the manufacturer SUNG WEI 06V0-A are marked: compare the three. There is also a number that starts with 0020 and varies depending on the unit; do not use it as the sole criterion.
Is it compatible with my Themaclassic F25E or my Themafast C25 E?
Check the status of each model in the compatibility sections; the pending variants are not validated. Registered application: this PCB for the Themafast C25 E, the Themafast F25 E H-MOD, the Thema C24 E V, the Thema Classic C25 E, and the Themaclassic F25E. In addition, each of the two Themaclassic with S1047000, SYMSI7.0, or 0310144400R18.
Does it work for another Saunier Duval that is not on the workshop list?
Check the status of each model in the compatibility sections; the pending variants are not validated. Application registered for the Themaclassic F 24 E and C 24 E, the Thema C 25 E, F 25 E and F 24 E, and the Isotwin F 24 E; for the Themafast C 24 E and C 30 E, there are only 2. Unconfirmed: send us a photo of the label and the specification plate from Contact, or call 911 17 77 77.
What is the relationship between 0310144400R18, SYMSI7.0, and S1047000?
0310144400R18 is the circuit code and SYMSI7.0 is the printed model; they are provided together. SYMSI7.0 is linked to the reference Saunier Duval S1047000. No official breakdown is available for this.
What does the R18 at the end mean and are there different versions?
without additional confirmation, explain the R18. It is presented as "electronic version" (3 relays 2+1, without additional control electronics) and provides for S1047000 and SYMSI7.0 the code 0310144400S19. Compare the complete code.
What does it come with and what should I check when installing it?
Our units use Omron relays with a 24 V DC coil and, depending on the unit, either transformer M24744-E or M24744-3E, a 1 A fuse (230 V), and terminals ALIM 230 V, V3V, and P1/P2; in two of them, the terminal TA is marked at 230 V. The installation manual for Themafast provides 24 V to the thermostat connector of the range, without mentioning this PCB: a technician should check the voltage of terminal TA before connecting one.
Who should install it?
A qualified technician: the PCB operates at 230 V and controls a gas boiler.
How to identify this PCB?
Compare the silkscreen, the distribution of the connectors, and the exact variant of the circuit with the photographs.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval SYMSI7.0 board · PCB 0310144400R18 for Themafast C25 E and Themaclassic F25E