Vaillant Group PM-02 PCB · 0020035375 for Themacondens F24
Application for the exact variant pending confirmation. To be confirmed: The PCB is the control unit of the boiler and is located behind the front panel, inside the control box. It is suspected when the boiler does not ignite, does not respond to the front panel, or displays erratic fault codes.
- Type of part
- Saunier Duval
- Status
- Refurbished
- internal SKU
- PLC055
- Warranty
- 1 year
Compatible Saunier Duval boilers
Saunier Duval. 0 confirmed compatibilities. There are 3 other models that we are still verifying.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Saunier Duval Thema Condens F 24 E | Saunier Duval | Unconfirmed |
|---|---|---|
| Saunier Duval Thema Condens F25 (2010-2015) | Saunier Duval | Unconfirmed |
| Saunier Duval Themacondens F24 | Saunier Duval | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Please confirm: Look for the code 0020035375 and the designation PM-02 on the PCB; indicate that the reference is usually printed on the circuit or on a side sticker.
- Check the rating plate of your boiler: the Saunier Duval Themacondens F24 is registered for this plate.
- Compare the number and position of the relays and connectors: note that different versions have been manufactured under the same reference.
- Compare with the 0020018478, the code provided for the Themafast Condens F 24 and F 30 and for the Thema Condens F 24 E: no documentation states whether it is the same PCB.
- if they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the Saunier Duval.
Common symptoms and faults
- 01
The boiler does not ignite or respond to any commands from the front panel.
Cause: To confirm: it is associated with a fault of this PCB.
- 02
Erratic fault codes appear that change for no apparent reason.
Cause: To confirm: as a sign of damaged PCB; consult your model's manual to interpret the fault code.
- 03
Strange clicking sounds can be heard or there are stuck relays in the circuit.
Cause: To confirm: it is related to this PCB.
- 04
Burnt traces or visible oxidation on the PCB.
Cause: To confirm: as a sign of damaged PCB.
- 05
The boiler restarts by itself during the operating cycles.
Cause: To confirm: it is associated with a fault of this PCB.
- 06
The boiler does not ignite: the fault code F28 appears (ignition fault).
Cause: Failed ignition: it could be gas, ignition, electrode, or PCB.
Have a technician check it.
- 07
The boiler shuts down during operation and does not restart (fault code F29).
Cause: Gas cut-off, flue gas recirculation, condensates, or faulty grounding.
Have a technician check it.
- 08
The boiler does not ignite and the display shows a fault code for ignition (F.28 or F.29).
Cause: Flame not detected. The most common causes are low gas pressure or a faulty ignition electrode.
Open the gas shut-off valve and press reset once. If it repeats, have an official technician check it.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F00 | Return temperature sensor (NTC2) disconnected. | Check if the sensor connector is loose. If it persists, have a technician check it: it could be the sensor, the cable, or the PCB. |
| F01 | Return temperature sensor (NTC5) disconnected. | Just like the F00: check the connector and, if it persists, have a technician check it. |
| F27 | Flame detection fault: the flame control is not reliable. | If it occurs when turning on or off, have a technician check it: it could be moisture in the electronics or the flame control. |
| F28 | Ignition fault: the burner does not ignite. | If it repeats, have a technician check it: it could be the gas, the ignition, or the PCB. |
| F29 | Flame loss during operation. | If it repeats, have a technician check it: it could be a gas cut-off, flue gas recirculation, or a faulty ground connection. |
| F61 | Gas valve activation fault. | Have a technician check it: it could be the wiring of the gas valve, its coils, or the electronics. |
| F62 | The gas valve does not close in time after the flame goes out. | Have a technician check it: the gas valve or the PCB are the suspects. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval
- Uniclima internal SKU
- PLC055
- Brand
- Saunier Duval
- Type of part
- Saunier Duval
- Units in stock
- 12 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Inventory — Power connector
- 230 V
- Auxiliary connector
- 24 V
- Inventory — Schrack Relay
- 24 V DC coil
- Inventory — Application indicated in inventory
- THEMACONDENS F24
- Additional data — Location
- Behind the front panel, inside the control box
- Additional information — Use
- Replacement spare part for Saunier Duval gas wall boilers
- Identification — Marked designation
- PM-02
- Identification — Marked code
- 0020035375
- Identification — Marked code
- PM-02
- Inventory data — Power connector
- 230 V
- Inventory data — Auxiliary connector
- 24 V
- Inventory data — Schrack relay
- 24 V DC coil
- Inventory data — Application indicated in inventory
- THEMACONDENS F24
- Additional markings
- Silkscreened PCB: PM-02. Auxiliary connector marked 24 V. SCHRACK relay: 24 V DC coil; the transcription does not provide its model.
- Pending applications to verify
- THEMACONDENS F24 — compatibility mentioned; pending confirmation with the exact variant. Consultation 10/24/2026 · 1 supplier; pending confirmation: Thema Condens F 24; Thema Condens F 24 E. Commercial statement for your sheet "PCB Saunier Duval (0020035375) Condens.", no certification of the unit. Confirm OEM reference, revision, configuration, and equipment variant before use.
- These signals are given by a single one for this PCB. We have not read an official fault table for the Themacondens F24, so we do not provide fault codes.
- To confirm: Saunier Duval Thema Condens F 24 E — it is listed with 0020035375; 2 websites list it with 0020018478.
- To confirm: Saunier Duval Thema Condens F25 (2010-2015) — it comes with 0020035375; one nomenclature (mixed rows) gives 0020212695, replaced by 0020247219.
- Not compatible or excluded: Saunier Duval Themafast Condens F 24 and F 30 — they have a different PCB code: 0020018478
- Do not confuse: 0020018478 — PCB provided for other Thema Condens: Themafast Condens F 24 and F 30, Thema Condens F 24 E and F 30 E (two websites) and Thema Condens F AS 24 E (spare parts catalog SAP 1652, "Main board") — It is another code: compare the marking on your PCB.
- Thema Condens F4, 0020035375, 1312BQ4207, 0020048962, 16530CC, 0020018224
- Join 0020035375 to the Thema Condens F 24; without official breakdown. Discrepancies: Registered designation: "Thema Condens F4" and the URL ends in 0020018478. They do not lower the registered designation.
- Pending confirmation of registered applications by model, variant, or programming: Saunier Duval Themacondens F24.