Chaffoteaux Pigma Green 25 Domestic Plate Heat Exchanger Ref. 65104333

Chaffoteaux Pigma Green 25 Domestic Plate Heat Exchanger Ref. 65104333

When you open the hot water tap, the Chaffoteaux Pigma Green 25 Plate Heat Exchanger is responsible for transferring heat from the primary circuit to the water, providing instant heat. If this part fails, you will notice that the water comes out lukewarm or has fluctuating temperatures, and the flow of domestic hot water may decrease. This heat exchanger is compatible with several boilers in the Pigma range, such as the Pigma 25 FF and the Pigma Green 25, among others. A technician must confirm through diagnosis whether it needs to be replaced if you experience these symptoms to restore the proper supply of hot water.

Catalogue reference
65104333
Warranty
1 year
VAT included Stock · 5 units
Compatibility

Chaffoteaux boilers compatible with reference 65104333

Plate heat exchanger with reference 65104333. 13 verified compatibilities: Pigma 25 FF and Pigma 30 FF.

Verified compatibility

Boiler modelFamilyVerification
Chaffoteaux Pigma 25 FFPigmaVerified
Chaffoteaux Pigma 30 FFPigmaVerified
Chaffoteaux Pigma Green 25PigmaVerified
Chaffoteaux Pigma Green 30PigmaVerified
Chaffoteaux Pigma EvoPigmaVerified
Chaffoteaux Alixia 24 FFAlixiaVerified
Chaffoteaux Alixia GreenAlixiaVerified
Chaffoteaux Niagara C 25 FFNiagaraVerified
Chaffoteaux Niagara C GreenNiagaraVerified
Chaffoteaux Talia 25 FFTaliaVerified
Chaffoteaux Talia GreenTaliaVerified
Chaffoteaux Urbia 25 FFUrbiaVerified
Chaffoteaux Urbia GreenUrbiaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 65104333 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 65104333. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the heat exchanger 65104333

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The water comes out hot at first and then suddenly cools down for no apparent reason.

    Cause: A partially obstructed PCB distributes the flow poorly, and the heat exchange becomes unstable.

    Open and close the tap a couple of times: if the fault is intermittent and not constant, it points more towards obstruction than breakage.

  • 02

    The hot water tap has very low pressure compared to the cold water tap.

    Cause: The narrow channels of the heat exchanger are the first to become clogged with scale and limit the flow that can pass through it.

    First, rule out the faucet aerator and the boiler inlet filter, which are much quicker and cheaper to check.

  • 03

    There is a water leak that only appears when the boiler is providing domestic hot water, not during heating.

    Cause: If the leak occurs only when the heat exchanger is under load, it indicates a crack in its plates or joints.

    Note if the dripping always coincides with the use of domestic hot water before replacing the part.

  • 04

    The performance of the domestic hot water has been gradually worsening over the months.

    Cause: Limescale accumulates progressively, so the symptom does not appear suddenly but worsens over time.

    Has maintenance or descaling been performed in the last few years? It significantly changes the initial diagnosis.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Chaffoteaux plate heat exchanger 65104333

Catalogue reference
65104333
Uniclima internal SKU
IDPPG25
Brand
Chaffoteaux
Type of part
Plate heat exchanger
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the plate heat exchanger 65104333

Is this domestic hot water heat exchanger compatible with a Chaffoteaux Pigma Green 25?
Yes, the Pigma Green 25 is on the list of boilers compatible with the Chaffoteaux Pigma Green 25 plate domestic hot water heat exchanger, reference IDPPG25.
Is it compatible with the Chaffoteaux Talia 25 FF?
Yes, the Talia 25 FF is listed among the compatible boilers for this heat exchanger.
When should I replace the domestic hot water heat exchanger in a Chaffoteaux Alixia boiler?
The technical diagnosis must confirm whether it is necessary to replace when there are faults in the heat exchange, leaks, or a decrease in performance.
How many models are compatible with the Chaffoteaux Pigma Green 25 plate domestic hot water heat exchanger?
This heat exchanger is compatible with a total of 13 boiler models.
What fault codes does the Chaffoteaux Pigma Green 25 plate heat exchanger have?
There are no documented fault codes for this product.

Spare parts related to Chaffoteaux Pigma

Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Chaffoteaux Pigma Green 25 Domestic Plate Heat Exchanger Ref. 65104333