Ariston AS 24 FF Pressure Gauge Ref. 65104234
The Ariston AS 24 FF manometer is a device that measures and controls the pressure of the boiler circuit. If it malfunctions, you will notice incorrect readings, which can cause the boiler to lock out due to a false low pressure or fail to regulate the temperature properly. This manometer is compatible with several Ariston boilers, such as the AS 24 CF and AS 24 FF models, as well as those from the BS, CLAS, EGIS, GENUS, and MATIS ranges, among others. It is recommended to replace it when it starts to show inaccuracies in the readings.
VAT included
Consult via WhatsAppAriston boilers compatible with reference 65104234
Pressure gauge with reference 65104234. 31 confirmed compatibilities: AS 24 CF and AS 24 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston AS 24 CF | Ariston AS | Contrasted |
| Ariston AS 24 FF | Ariston AS | Contrasted |
| Ariston BS 24 CF | Ariston BS | Contrasted |
| Ariston BS 24 FF | Ariston BS | Contrasted |
| Ariston BS II 24 FF | Ariston BS | Contrasted |
| Ariston CLAS 24 FF | Ariston CLAS | Contrasted |
| Ariston CLAS 28 FF | Ariston CLAS | Contrasted |
| Ariston CLAS 32 FF | Ariston CLAS | Contrasted |
| Ariston CLAS EVO | Ariston CLAS | Contrasted |
| Ariston CLAS PREMIUM | Ariston CLAS | Contrasted |
| Ariston CLAS PREMIUM EVO | Ariston CLAS | Contrasted |
| Ariston EGIS 24 CF | Ariston EGIS | Contrasted |
| Ariston EGIS 24 FF | Ariston EGIS | Contrasted |
| Ariston EGIS PLUS | Ariston EGIS | Contrasted |
| Ariston EGIS PREMIUM | Ariston EGIS | Contrasted |
| Ariston GENUS 32 FF | Ariston GENUS | Contrasted |
| Ariston GENUS 36 FF | Ariston GENUS | Contrasted |
| Ariston GENUS EVO | Ariston GENUS | Contrasted |
| Ariston GENUS PREMIUM EVO | Ariston GENUS | Contrasted |
| Ariston MATIS 24 CF | Ariston MATIS | Contrasted |
| Ariston MATIS 24 FF | Ariston MATIS | Contrasted |
| Ariston ALIXIA GREEN IN | Chaffoteaux ALIXIA | Contrasted |
| Ariston ALIXIA IN | Chaffoteaux ALIXIA | Contrasted |
| Ariston PIGMA GREEN IN | Chaffoteaux PIGMA | Contrasted |
| Ariston TALIA GREEN IN | Chaffoteaux TALIA | Contrasted |
| Ariston TALIA IN | Chaffoteaux TALIA | Contrasted |
| Ariston TALIA ZELIOS IN | Chaffoteaux TALIA | Contrasted |
| Ariston ECOBLU 25 IN | Ecoflam ECOBLU | Contrasted |
| Ariston ECOBLU 35 IN | Ecoflam ECOBLU | Contrasted |
| Ariston ECOSI 25 IN | Ecoflam ECOSI | Contrasted |
| Ariston ECOSI 30 IN | Ecoflam ECOSI | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 65104234 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 65104234. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge 65104234 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The needle does not indicate pressure or gets stuck at one end, not moving even if the actual pressure changes.
Cause: The internal mechanism has jammed and does not transfer the circuit pressure to the needle.
Fill the circuit with the filling key until it reaches 1-1.5 bar and check if the needle reacts to the change.
- 02
The gauge is fogged on the inside or broken, and the scale from 0 to 4 bar cannot be distinguished.
Cause: Moisture has entered the body of the pressure gauge or the glass has been hit.
Check if the condensation is only on the outer glass or also between the glass and the sphere, to determine if it's a cleaning issue or a fault.
- 03
Water is dripping from the base of the pressure gauge, where it connects to the boiler.
Cause: The gasket or the thread of the base has lost its seal over time and use.
Dry the area well and observe for a few minutes with the boiler running to confirm that the drop is coming from the base and not from another nearby fitting.
- 04
The pressure seems normal at first glance, but the boiler is still showing a pressure fault.
Cause: The pressure gauge can visually read correctly while the boiler's internal circuit uses a different measurement point.
Check the manual for the exact fault code and verify if it corresponds to pressure before assuming that the pressure gauge is the culprit.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for Ariston pressure gauge 65104234
- Catalogue reference
- 65104234
- Brand
- Ariston
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure gauge
- 0-4 bar
- Dial color
- White