Boiler Pressure Gauge Fagor CE 20E N Ref. MU0816300
When you open the tap or turn on the heating, the pressure gauge of the Fagor CE 20E N boiler (Ref. MU0816300) is responsible for measuring and controlling the pressure of the circuit. If this part fails, you will notice incorrect readings, which can cause the boiler to lock due to a false lack of pressure or not regulate the temperature properly. It is compatible with several models, such as the CE 20E, CE-20E N, and others from the Fagor Contract range. It is recommended to replace the pressure gauge when you observe these irregularities in its operation.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MU0816300
Manometer with reference MU0816300. Four confirmed compatibilities: CE 20E and CE-20E N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor CE 20E | Fagor Contract CE 20E | Contrasted |
| Fagor CE-20E N | Fagor Contract CE 20E | Contrasted |
| Fagor Contract CE 20E 1N | Fagor Contract CE 20E | Contrasted |
| Fagor CA 20E N | Fagor Contract CA 20E | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number MU0816300 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0816300. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge MU0816300 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gauge reads zero even though I have filled the boiler and I can feel the water circulating.
Cause: If the needle does not show the actual pressure, it is because the internal mechanism of the manometer has lost its range, not because there is a lack of water in the circuit.
Bleed the radiators and refill until the usual cold pressure; if the needle remains at zero, the fault is in the pressure gauge itself.
- 02
The needle has gone to the maximum scale and does not drop even when I bleed the circuit.
Cause: A mechanism jammed by scale or dirt remains fixed at one end instead of following the actual pressure.
Gently tap the dial and check if the needle releases; if it doesn't budge, it's not a circuit pressure issue but rather a problem with the indicator.
- 03
I see a droplet of water coming out from underneath the pressure gauge.
Cause: The gasket or the connection fitting to the boiler degrades over time, and water finds a way out through there before reaching the measuring mechanism.
Dry the area, tighten the fitting carefully without forcing it, and check in a few hours if the moisture reappears before replacing the part.
- 04
I can't see anything on the dial, it's fogged up or seems broken inside.
Cause: The moisture that enters through a damaged joint ends up condensing inside the glass, making the indicator unreadable even though the mechanism works.
Check if the condensation disappears by drying the boiler with it turned off for a while; if it fogs up again, the pressure gauge's tightness is compromised.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor MU0816300 pressure gauge data sheet
- Catalogue reference
- MU0816300
- Brand
- Fagor
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure scale / range
- 0-4 bar