Chaffoteaux Niagara Delta 30 FF Pressure Gauge Ref. 61305005
The pressure gauge Chaffoteaux Niagara Delta 30 FF measures and controls the water circuit pressure in the boiler. If it fails, you may notice incorrect readings, which can cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. This pressure gauge is compatible with the models Niagara Delta 24 FF, Niagara Delta 28 FF, and Niagara Delta 30 FF, as well as the Niagara Green. It is advisable to replace it when you observe issues with pressure readings or boiler lockout.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61305005
Pressure gauge with reference 61305005. Four confirmed compatibilities: Niagara Delta 24 FF and Niagara Delta 28 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Niagara Delta 24 FF | Niagara Delta | Contrasted |
| Chaffoteaux Niagara Delta 28 FF | Niagara Delta | Contrasted |
| Chaffoteaux Niagara Delta 30 FF | Niagara Delta | Contrasted |
| Chaffoteaux Niagara Green | Niagara Green | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 61305005 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61305005. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the manometer 61305005 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure reading neither rises nor falls; it remains stuck.
Cause: The internal mechanism of the part is jammed and does not reflect the actual pressure of the circuit.
Bleed the air from the circuit and check the cold pressure; if the reading still doesn't change after bleeding, the fault is in the part.
- 02
There is a drop or a ring of moisture at the base of the part.
Cause: The gasket or capillary deteriorates with heat and loses tightness.
Dry the area, keep the boiler running, and check again: if the humidity reappears only there, the problem is not a poorly tightened fitting.
- 03
The boiler locks out or indicates a pressure fault without you having touched the filling.
Cause: A contact that does not close properly sends a fault reading to the control board even if the circuit is correct.
Before resetting, note the actual pressure of the filling system and compare it with what the boiler indicates when blocked.
- 04
The water takes longer than usual to heat up, or the pump does not start when it should.
Cause: A contact that does not close when the set temperature is reached leaves the pump without the command it expects.
With the boiler hot, check if the contact of the part closes when reaching the operating temperature, before replacing it.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 09 | The water pressure in the system is too high. | If the pressure gauge shows a pressure higher than 3 bars, it indicates that the pressure is excessive. You should check the safety valve and adjust the pressure to prevent damage to the boiler. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux pressure gauge 61305005 data sheet
- Catalogue reference
- 61305005
- Brand
- Chaffoteaux
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Cover
- Transparent (side view in the available photo)
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux Niagara Delta 28 FF Manual (PDF)Document © Chaffoteaux, provided as a technical reference.