Chaffoteaux Niagara Delta 30 FF Pressure Gauge Ref. 61305005

Chaffoteaux Niagara Delta 30 FF Pressure Gauge Ref. 61305005

The pressure gauge Chaffoteaux Niagara Delta 30 FF measures and controls the water circuit pressure in the boiler. If it fails, you may notice incorrect readings, which can cause the boiler to lock out due to a false lack of pressure or not regulate the temperature properly. This pressure gauge is compatible with the models Niagara Delta 24 FF, Niagara Delta 28 FF, and Niagara Delta 30 FF, as well as with the Niagara Green. A technician should confirm through diagnosis whether it needs to be replaced when you observe issues with pressure readings or boiler lockout.

Catalogue reference
61305005
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Chaffoteaux boilers compatible with reference 61305005

Pressure gauge with reference 61305005. Four confirmed compatibilities: Niagara Delta 24 FF and Niagara Delta 28 FF.

Verified compatibility

Boiler modelFamilyVerification
Chaffoteaux Niagara Delta 24 FFNiagara DeltaVerified
Chaffoteaux Niagara Delta 28 FFNiagara DeltaVerified
Chaffoteaux Niagara Delta 30 FFNiagara DeltaVerified
Chaffoteaux Niagara GreenNiagara GreenVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 61305005 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61305005. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the manometer 61305005

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure reading neither rises nor falls; it remains stuck.

    Cause: The internal mechanism of the part is jammed and does not reflect the actual pressure of the circuit.

    Bleed the air from the circuit and check the cold pressure; if the reading still doesn't change after bleeding, the fault is in the part.

  • 02

    There is a drop or a ring of moisture at the base of the part.

    Cause: The gasket or capillary deteriorates with heat and loses tightness.

    Dry the area, keep the boiler running, and check again: if the humidity reappears only there, the problem is not a poorly tightened fitting.

  • 03

    The boiler locks out or indicates a pressure fault without you having touched the filling.

    Cause: A contact that does not close properly sends a fault reading to the control board even if the circuit is correct.

    Before resetting, note the actual pressure of the filling system and compare it with what the boiler indicates when blocked.

  • 04

    The water takes longer than usual to heat up, or the pump does not start when it should.

    Cause: A contact that does not close when the set temperature is reached leaves the pump without the command it expects.

    With the boiler hot, check if the contact of the part closes when reaching the operating temperature, before replacing it.

Chaffoteaux fault codes that require diagnosis

CodeFaultTechnical checks
09The water pressure in the system is too high.If the pressure gauge shows a pressure higher than 3 bars, it indicates that the pressure is excessive. You should check the safety valve and adjust the pressure to prevent damage to the boiler.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Chaffoteaux pressure gauge 61305005 data sheet

Catalogue reference
61305005
Uniclima internal SKU
MPND30FF
Brand
Chaffoteaux
Type of part
Pressure gauges & aquastats
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Cover
Transparent (side view in the available photo)
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the pressure gauge 61305005

Is this part compatible with a Chaffoteaux Niagara Delta 24 FF?
Yes, the Niagara Delta 24 FF is listed among the compatible boilers in this document.
Does this part work for a Chaffoteaux Niagara Delta 28 FF?
Yes, the Niagara Delta 28 FF is also included in the list of compatible boilers.
Is it compatible with the Chaffoteaux Niagara Delta 30 FF?
Yes, this part is compatible with the Niagara Delta 30 FF, which is one of the listed models.
How many models are compatible with the pressure gauge Chaffoteaux Niagara Delta 30 FF Ref. 61305005?
The manometer is compatible with a total of 4 boiler models.
What fault code is documented for this product?
The documented fault code for this pressure gauge is 09.
What is the reference for this pressure gauge?
MPND30FF is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Chaffoteaux Niagara Delta 30 FF Pressure Gauge Ref. 61305005