Chaffoteaux Pigma Green 25 Pressure Gauge Ref. 60000725
Chaffoteaux Pigma Green 25 pressure gauge Ref. 60000725 is a device that measures and controls the pressure of the boiler circuit. Its failure can lead to incorrect readings, which may cause the boiler to lock out due to a false low pressure or fail to regulate the temperature properly. This pressure gauge is compatible with models such as Pigma 25 CF, Pigma 25 FF, Alixia 25 CF, among others. It is recommended to replace it when you notice erroneous readings or instability in the pressure.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 60000725
Pressure gauge with reference 60000725. 35 verified compatibilities: Alixia 24 FF and Alixia 25 CF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Alixia 24 FF | Alixia | Contrasted |
| Chaffoteaux Alixia 25 CF | Alixia | Contrasted |
| Chaffoteaux Alixia 25 FF | Alixia | Contrasted |
| Chaffoteaux Alixia 18 FF | Alixia | Contrasted |
| Chaffoteaux Alixia Green 24 | Alixia | Contrasted |
| Chaffoteaux Alixia Green 29 | Alixia | Contrasted |
| Chaffoteaux Alixia Simple 18 CF | Alixia | Contrasted |
| Chaffoteaux Alixia Simple 24 FF | Alixia | Contrasted |
| Chaffoteaux Pigma 25 CF | Pigma | Contrasted |
| Chaffoteaux Pigma 25 FF | Pigma | Contrasted |
| Chaffoteaux Pigma 30 FF | Pigma | Contrasted |
| Chaffoteaux Pigma Green 25 FF | Pigma | Contrasted |
| Chaffoteaux Pigma Green 30 FF | Pigma | Contrasted |
| Chaffoteaux Talia 25 CF | Talia | Contrasted |
| Chaffoteaux Talia 25 FF | Talia | Contrasted |
| Chaffoteaux Talia 30 CF | Talia | Contrasted |
| Chaffoteaux Talia 30 FF | Talia | Contrasted |
| Chaffoteaux Talia System 25 FF | Talia | Contrasted |
| Chaffoteaux Talia System 30 FF | Talia | Contrasted |
| Chaffoteaux Talia Green | Talia | Contrasted |
| Chaffoteaux Urbia 25 CF | Urbia | Contrasted |
| Chaffoteaux Urbia 25 FF | Urbia | Contrasted |
| Chaffoteaux Urbia 30 CF | Urbia | Contrasted |
| Chaffoteaux Urbia 30 FF | Urbia | Contrasted |
| Chaffoteaux Urbia 35 FF | Urbia | Contrasted |
| Chaffoteaux Urbia Green 25 FF | Urbia | Contrasted |
| Chaffoteaux Urbia Green 30 FF | Urbia | Contrasted |
| Chaffoteaux Niagara C 25 CF | Niagara C | Contrasted |
| Chaffoteaux Niagara C 25 FF | Niagara C | Contrasted |
| Chaffoteaux Niagara C 30 FF | Niagara C | Contrasted |
| Chaffoteaux Niagara C Green 25 | Niagara C | Contrasted |
| Chaffoteaux Niagara C Green 35 | Niagara C | Contrasted |
| Chaffoteaux Serelia 25 FF | Serelia | Contrasted |
| Chaffoteaux Serelia 30 FF | Serelia | Contrasted |
| Chaffoteaux Serelia Green 25 FF | Serelia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 60000725 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60000725. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge 60000725 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The needle of the manometer does not move or gets stuck on the same number even when the pressure in the circuit changes.
Cause: The internal mechanism is a bellows or spring that moves with the water pressure; limescale and sediment in the circuit can block it over time.
Bleed a little air from a radiator or slightly fill the circuit with the filling key and observe if the needle reacts immediately: if it doesn't move, the mechanism is blocked.
- 02
The pressure cannot be read because the green and red sectors of the dial are not clearly distinguishable.
Cause: The protective glass fogs up or gets dirty over time, and it can also discolor due to the heat near the boiler.
Clean the exterior glass carefully before discarding the part: sometimes that's enough to restore the reading.
- 03
The glass of the dial is broken or scratched and does not allow a clear view of the needle.
Cause: It is the most exposed part of the pressure gauge and gets damaged from impacts during the handling of the boiler or the circuit itself.
Check if, despite the broken glass, the needle moves normally when bleeding or filling the circuit: if the mechanism responds well, the problem is only with the glass.
- 04
The needle moves, but it shows a pressure that does not match what another manometer indicates or with the feel of the installation.
Cause: The mechanism may have lost accuracy with use, especially if the circuit has experienced pressure shocks or repeated drainings.
Before changing it, bleed the air from the circuit and check the cold pressure: a low reading after bleeding is usually a lack of water, not a faulty pressure gauge.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux pressure gauge 60000725
- Catalogue reference
- 60000725
- Brand
- Chaffoteaux
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days