Pressure Gauge Junkers ZWE 24 Ref. 87172080280

Pressure Gauge Junkers ZWE 24 Ref. 87172080280

10 €VAT includedIn stock · 1 unit

Black dial pressure gauge with a red needle, featuring a printed scale from 0 to 4 bar, used to measure the pressure of the boiler circuit. It should be replaced when the needle doesn't move, reads off-scale, or there is a leak at the connection thread. The part does not have a readable manufacturer or reference code.

Spare parts related to Junkers ZW20-1AME23 (part model)

Compatibility

Junkers boilers compatible with reference 87172080280

Manometer with reference 87172080280. Six confirmed compatibilities with two independent sources: ZW20-1AME23 and ZW20J. Verify the printed reference on your part before purchasing.

Compatibility confirmed

Boiler modelFamilyVerification
Junkers ZW20-1AME23ZW20-1AME23 (part model)Confirmed · 2 sources
Junkers ZW20JZW20-1AME23 (part model)Confirmed · 2 sources
Junkers ZSEuroline (series ZW/ZS)Confirmed · 2 sources
Junkers ZSREuroline (series ZW/ZS)Confirmed · 2 sources
Junkers ZWROld Cerastar (ZR/ZWR series)Confirmed · 2 sources
Junkers ZROld Cerastar (ZR/ZWR series)Confirmed · 2 sources

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87172080280 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Locate the reference printed on the body of the pressure gauge you have installed: it should indicate 87172080280.
  2. Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
  3. Compare the connections and the body with the original part before installing.
  4. If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Diagnosis

Symptoms and faults resolved by pressure gauge 87172080280

The pressure gauge shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

The needle is stuck on a number and never moves, whether you load or bleed water.

Cause: The inner Bourdon tube has seized, something common when dirt or lime has entered through the thread.

Gently tap on the glass with the boiler turned off; if the needle doesn't react at all, the mechanism is blocked.

The pressure indicated by the pressure gauge does not match what you know the installation has.

Cause: The mechanism has lost precision over time and no longer calibrates the reading accurately.

Compare the reading with another reference manometer at the same load point before considering the instrument faulty.

Water is leaking or there is a ring of rust on the connection thread of the pressure gauge.

Cause: The thread's seal has deteriorated and water is leaking at low pressure.

Check if tightening the fitting a bit more solves the leak before buying a new one; if it continues to drip, it's the part.

The dial is broken or so fogged up that no numbers can be read.

Cause: It is physical damage to the body or moisture entering the mechanism, not a fault with the boiler.

Check if you can still see the needle moving even if you can't read the number clearly; that indicates the mechanism itself is working.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers pressure gauge 87172080280

OEM reference
87172080280
Brand
Junkers
Type of part
Pressure gauges - Aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure gauge
0-4 bar
label
Before purchasing
  • The manufacturer of this pressure gauge is not listed on the part; it could not be confirmed with external sources in this session.
  • There is no readable reference code on the part. Check that the scale (0-4 bar) matches your pressure gauge and that your boiler model is on the list of compatible ones before ordering.
Frequently Asked Questions

Frequently Asked Questions about Pressure Gauge 87172080280

Is this pressure gauge suitable for the ZWE24-2KDG boiler?
Yes, the ZWE24-2KDG is the main model of this datasheet and is confirmed as compatible.
What pressure scale does the pressure gauge of the ZWE24-2KDG have?
0 to 4 bar, according to the printed dial.
Is the manufacturer of the pressure gauge for the CL-100 known?
The part does not have any markings; the manufacturer could not be identified and there is no legible reference code.
Why does the pressure gauge of the MINI-8K21 series need to be changed?
When the needle does not move, reads out of scale, or there is a leak at the connection thread.
Is this pressure gauge suitable for any boiler with a 0-4 bar scale even if it's not on the list?
Not necessarily; compatibility is only confirmed with the boiler models listed in this sheet (ZWE24-2KDG, ZE24, ZR, ZSR, ZWR, CL-100, KS, MINI-8K21, MINI-11K31).
Is it the same pressure gauge used in the Junkers ZW20 KD?
It shares the same catalog reference (87172080280) and the same range of 0-4 bar, but each datasheet confirms compatibility only with the boiler models it lists.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model