Pressure Gauge 0-4 Bar Boiler ZWE24-2KDG - Ref. 87172080280

Pressure Gauge 0-4 Bar Boiler ZWE24-2KDG - Ref. 87172080280

Stock · 1 unit

The 0-4 bar pressure gauge of the ZWE24-2KDG boiler measures and controls the pressure of the circuit. If it fails, it may display incorrect readings, which can cause the boiler to lock out due to a false low pressure or fail to regulate the temperature properly. This part is compatible with several models, such as ZW20-1AME23, ZW20J, as well as the Euroline series and old Cerastar. It is advisable to replace it when you notice that the readings are incorrect or the boiler is experiencing operational issues related to pressure.

VAT included

Compatibility

Junkers boilers compatible with reference 87172080280

Pressure gauge with reference 87172080280. Six confirmed compatibilities: ZW20-1AME23 and ZW20J.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZW20-1AME23ZW20-1AME23 (part model)Contrasted
Junkers ZW20JZW20-1AME23 (part model)Contrasted
Junkers ZSEuroline (series ZW/ZS)Contrasted
Junkers ZSREuroline (series ZW/ZS)Contrasted
Junkers ZWROld Cerastar (ZR/ZWR series)Contrasted
Junkers ZROld Cerastar (ZR/ZWR series)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87172080280 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87172080280. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure gauge 87172080280 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The needle is stuck on a number and never moves, whether you load or bleed water.

    Cause: The inner Bourdon tube has seized, something common when dirt or lime has entered through the thread.

    Gently tap the glass while the boiler is off; if the needle does not respond, the mechanism is stuck.

  • 02

    The pressure indicated by the pressure gauge does not match what you know the installation has.

    Cause: The mechanism has lost precision over time and no longer calibrates the reading accurately.

    Compare the reading with another reference manometer at the same load point before considering the instrument faulty.

  • 03

    Water is leaking or there is a ring of rust on the connection thread of the pressure gauge.

    Cause: The thread's seal has deteriorated and water is leaking at low pressure.

    Check if tightening the fitting a bit more solves the leak before buying a new one; if it continues to drip, it's the part.

  • 04

    The dial is broken or so fogged up that no numbers can be read.

    Cause: It is physical damage to the body or moisture entering the mechanism, not a fault with the boiler.

    Check if you can still see the needle moving even if you can't read the number clearly; that indicates the mechanism itself is working.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers pressure gauge 87172080280

Catalogue reference
87172080280
Brand
Junkers
Type of part
Pressure gauges & aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure gauge
0-4 bar
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure gauge 87172080280

Is this pressure gauge suitable for the ZWE24-2KDG boiler?
Yes, the ZWE24-2KDG is the main model of this datasheet and is confirmed as compatible.
What pressure scale does the pressure gauge of the ZWE24-2KDG have?
0 to 4 bar, according to the printed dial.
Why does the pressure gauge of the boiler ZW20-1AME23 need to be replaced?
When the needle does not move, reads out of scale, or there is a leak at the connection thread.
Is this pressure gauge suitable for any boiler with a 0-4 bar scale even if it's not on the list?
Not necessarily; compatibility is only confirmed with the boiler models listed in this document: ZW20-1AME23, ZW20J, ZS, ZSR, ZWR, and ZR.
What is the reference for this manometer?
The reference for the pressure gauge is MPBZWE24.
How many models are compatible with this manometer?
A total of 6 models are compatible.

Spare parts related to Junkers ZW20-1AME23 (part model)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Pressure Gauge 0-4 Bar Boiler ZWE24-2KDG - Ref. 87172080280