Junkers Thermometer for Mini, ZSR, and ZWR Boilers
When you open the hot water tap or turn on the heating, the Junkers thermometer for Mini boilers, ZSR, and ZWR is responsible for measuring and controlling the temperature of the circuit. If this part fails, you will notice incorrect readings, which can cause the boiler to lock due to a false lack of pressure or not regulate the temperature properly. This thermometer is compatible with models such as ZR 18-2 KE/AE, ZR 24-2 KE/AE, ZWR 18-2 KE/AE, ZWR 24-2 KE/AE, ZSR 18-2 KE/AE, and ZSR 24-2 KE/AE, among others. It should be replaced when you experience problems with temperature or pressure measurement.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 87172080270
Pressure gauge with reference 87172080270. Six confirmed compatibilities: ZR 18-2 KE/AE and ZR 24-2 KE/AE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZR 18-2 KE/AE | ZR / ZWR / ZSR -2 KE/AE (old range / MINI) | Contrasted |
| Junkers ZR 24-2 KE/AE | ZR / ZWR / ZSR -2 KE/AE (old range / MINI) | Contrasted |
| Junkers ZWR 18-2 KE/AE | ZR / ZWR / ZSR -2 KE/AE (old range / MINI) | Contrasted |
| Junkers ZWR 24-2 KE/AE | ZR / ZWR / ZSR -2 KE/AE (old range / MINI) | Contrasted |
| Junkers ZSR 18-2 KE/AE | ZR / ZWR / ZSR -2 KE/AE (old range / MINI) | Contrasted |
| Junkers ZSR 24-2 KE/AE | ZR / ZWR / ZSR -2 KE/AE (old range / MINI) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 87172080270 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 87172080270. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge 87172080270 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The needle does not indicate the temperature or remains fixed at a value.
Cause: The internal mechanism of the thermostat has seized up and no longer translates the heat from the circuit into needle movement.
Touch the pipe near the sensor: if you feel it is hot but the needle does not rise, the thermometer is the problem and not the boiler.
- 02
There is no visible movement when heating the boiler circuit.
Cause: The sensor is not properly seated in its sleeve and does not capture the actual heat of the water.
Check that the sensor is fully inserted into the sleeve and properly seated, without any play, before declaring the part faulty.
- 03
The glass of the dial is broken and doesn't allow the scale to be read.
Cause: It is a mechanical break of the front glass, not a fault of the measuring mechanism.
Check if the needle moves when touched despite the broken glass; if it moves, the problem is only with the reading, not with the mechanism.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Junkers pressure gauge 87172080270
- Catalogue reference
- 87172080270
- Brand
- Junkers
- Type of part
- Pressure gauges - Aquastats
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Temperature scale
- 20-120 °C
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Junkers ZWR 24-2 KE/AE Manual (PDF)Document © Junkers, provided as a technical reference.