Pressure Gauge Junkers Euroline ZW23 1 AE 23 S3705 Ref. 87387036010
In the Junkers Euroline boilers, the Junkers Euroline ZW23 1 AE 23 S3705 Pressure Gauge Ref. 87387036010 measures and controls the pressure of the circuit. If it fails, you may notice incorrect readings that cause the boiler to lock out due to a false lack of pressure or poor temperature regulation. This pressure gauge is compatible with models such as ZW23-1 AE, ZW24-1 E LH AE, and ZW24-2 E LH AE, among others. It is recommended to replace it if you observe that the needle is not indicating correctly or if the boiler is experiencing operational issues related to pressure.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 87387036010
Pressure gauge with reference 87387036010. Four confirmed compatibilities: ZW23-1 AE and ZW24-1 E LH AE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZW23-1 AE | Euroline | Contrasted |
| Junkers ZW24-1 E LH AE | Euroline | Contrasted |
| Junkers ZW24-2 E LH AE | Euroline | Contrasted |
| Junkers ZW24-2 E LH AE | Ceraclass | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 87387036010 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 87387036010. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the manometer 87387036010 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gauge does not reach the green zone and remains in the lower area, even though the boiler has been on for a while.
Cause: The mechanical indicator does not reflect the actual pressure of the circuit because the spring or the internal bellows have lost travel.
Bleed the circuit and fill it up to the usual level when cold. Check if the needle responds during the filling process.
- 02
The yellow needle is stuck at the same point regardless of what happens with the pressure.
Cause: The internal mechanism of the indicator is jammed or has residues, which prevents it from moving even when the pressure changes.
Gently tap the casing and see if the needle moves. If it does not react to bleeding or refilling, the blockage is inside the indicator.
- 03
I don't know if I really have pressure because the gauge gives different readings depending on the day.
Cause: A loose brass fitting or a damaged internal gasket allows air to enter the measuring chamber, affecting the reading.
Check that the brass fitting is properly tightened to the boiler and that there is no moisture or dripping around before replacing the part.
- 04
The boiler warns of low pressure even though the indicator seems to be within the range.
Cause: The visual reading of the indicator does not match the actual pressure of the circuit, which can lead to incorrect decisions.
Compare the reading of this indicator with another measurement point in the circuit, if available, before declaring the part defective.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Junkers pressure gauge 87387036010
- Catalogue reference
- 87387036010
- Brand
- Junkers
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure range
- 0-4 bar
- Scale of the secondary indicator
- 1-2-3, with a green/gray strip for the work area
- Needle color
- yellow
- Body
- black plastic head on brass fitting