The Heatline / Demrad-Demirdöküm Air Pressure Switch Ref. 3003200032 is a component that checks the air pressure in the boiler and authorizes its operation. When it fails, the boiler does not start or gets locked, even if the actual pressure is correct, which may indicate a problem with the pressure switch. This model is compatible with various boilers, such as the Heatline Compact, Vizo, IG, System, Capriz, and Hydroline, as well as with the Demrad HK C, D, and B models, among others. It is recommended to replace the pressure switch when faults in air pressure are detected or if symptoms of locking in the boiler appear.

VAT included

Compatibility

Airsol boilers compatible with reference 3003200032

Pressure switch with reference 3003200032. 27 verified compatibilities: Compact C24 and Compact S24.

Proven compatibility

Boiler modelFamilyVerification
Airsol Compact C24Heatline CompactContrasted
Airsol Compact S24Heatline CompactContrasted
Airsol Compact S24SHeatline CompactContrasted
Airsol Compact S20SHeatline CompactContrasted
Airsol Compact S30Heatline CompactContrasted
Airsol Vizo 24Heatline VizoContrasted
Airsol IG24Heatline IGContrasted
Airsol System S20Heatline SystemContrasted
Airsol System S24Heatline SystemContrasted
Airsol System S30Heatline SystemContrasted
Airsol Capriz 25Heatline CaprizContrasted
Airsol Capriz 25SHeatline CaprizContrasted
Airsol Capriz 28Heatline CaprizContrasted
Airsol Capriz 28SHeatline CaprizContrasted
Airsol Hydroline B24Heatline HydrolineContrasted
Airsol HK C 124Demrad HK CContrasted
Airsol HK C 224Demrad HK CContrasted
Airsol HK D 120Demrad HK DContrasted
Airsol HK D 124Demrad HK DContrasted
Airsol HK D 224Demrad HK DContrasted
Airsol HK B 124Demrad HK BContrasted
Airsol HK B 224Demrad HK BContrasted
Airsol AdenDemrad othersContrasted
Airsol SolarisDemrad othersContrasted
Airsol TayrosDemrad othersContrasted
Airsol Kalisto BitermicDemrad othersContrasted
Airsol Kalisto MonoDemrad othersContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 3003200032 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 3003200032. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 3003200032 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, the fan starts, but it stops and locks out before the flame ignites.

    Cause: The air pressure switch does not close the contact in time, and the control board interprets that there is not enough extraction, so it cuts off the gas cycle for safety.

    Before changing it, check that the silicone tubes going from the pressure switch to the venturi/extractor are not disconnected, bent, or have accumulated water.

  • 02

    The flue fault appears and disappears on its own, especially on rainy or very windy days.

    Cause: Condensate water can remain in the pressure intake pipes and alter the signal reaching the pressure switch, even if the fan is functioning properly.

    Bleed the pipes by blowing carefully and check that they have a slope towards the extractor to prevent water accumulation.

  • 03

    The extractor spins normally, but the burner never starts.

    Cause: The internal contact of the pressure switch may be dirty or oxidized and may not switch even if the generated pressure is correct.

    With the extractor running, use a multimeter to check if the pressure switch closes the contact; if it doesn't, that's where the problem lies.

  • 04

    The blockage started right after cleaning or touching the flue gas outlet.

    Cause: If the outdoor terminal is somewhat obstructed, the extractor does not create the necessary depression and the pressure switch, even if it is functioning properly, does not close.

    Check the external outlet terminal and the duct section for any obstructions before discarding the part.

Fault codes for Airsol that this part resolves.

CodeFaultDiagnosis and solution
Air pressure switch faultAir pressure switch fault: the flue circuit depression/draught is not validated.The Huba air pressure switch (ref. 3003200032) does not switch due to lack of differential pressure (flue/intake obstruction, dirty/deficient fan, obstructed pressure switch tube) or due to its own fault; check with a differential manometer and inspect the tube, fan, and flue outlet before replacing it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Airsol 3003200032 pressure switch datasheet

Catalogue reference
3003200032
Brand
Airsol
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Printed reference
3003200032
Manufacturer code
605.99643
Switching pressure
85/70 Pa
Electrical contact
0.2(0.1) A / 30V~ (approximate reading)
Dielectric strength
24 kV
Frequently Asked Questions

Frequently asked questions about the pressure switch 3003200032

Is this pressure switch Ref. 3003200032 compatible with a Heatline S24?
Yes, the Heatline S24 (S24, S24 Compact, S24S) is on the list of compatible boilers for this part.
What fault does this pressure switch cause in a Demrad/Demirdöküm Aden?
If it does not detect the correct air pressure generated by the extractor (85/70 Pa), it blocks the ignition of the burner.
Is the same pressure switch Ref. 3003200032 compatible with the Heatline Capriz 28 and the Heatline S30?
Yes, both models, Heatline Capriz 28 and Heatline S30 (S30, S30 Compact, S30S), are on the list of compatible boilers.
What code is engraved on this pressure switch besides the reference 3003200032?
The manufacturer code 605.99643, along with a batch code (for example BVZBAG).