Honeywell Pressure Switch C6065FH1383:2 (Azbil Corporation) Saunier Duval STY 300
RefurbishedSaunier DuvalPressure switchesAzbil Corporation

Honeywell Pressure Switch C6065FH1383:2 (Azbil Corporation) Saunier Duval STY 300

Stock · 5 units

Honeywell C6065FH1383:2 pressure switch with micro switch, manufactured by Azbil Corporation and made in China. It is a pressure switch: it changes the state of an electrical contact (NC/NO/C scheme) according to the detected pressure difference, with a set point of 0.72 mbar and a maximum switching at 6 mbar. It is replaced when it fails and causes the boiler to lock out.

VAT included

Compatibility

Compatible Saunier Duval boilers

Pressure switch. A proven compatibility: Duval STY 300.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval STY 300SaunierContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch resolves

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, you hear the fan for a moment, and then it stops and remains locked.

    Cause: The pressure switch does not detect the depression generated by the fan, and the boiler cuts off the gas for safety before igniting.

    Check that the silicone tubes going from the fan to the pressure switch are not bent, loose, or cracked.

  • 02

    The lockout occurs right after the fan starts, before the flame appears.

    Cause: The pressure switch must close its contact for the PCB to authorize the gas valve, and if it does not switch in time, the cycle is aborted.

    Check that the fan spins freely and at a good speed; a loose one does not generate enough pressure.

  • 03

    The fault is particularly noticeable when it's windy or when the flue is dirty.

    Cause: The pressure switch is sensitive to the actual pressure difference in the duct, and a restricted venting alters the reading even if the component is fine.

    Check the flue terminal and the duct for any blockages, nests, or dirt before replacing the pressure switch.

  • 04

    The boiler lockout code indicates a pressure switch or ventilation fault.

    Cause: It is the warning given by the boiler when it does not receive the expected signal from this component within the safety time.

    Confirm in your model's manual that this code corresponds to the pressure switch, as some manufacturers use the same code for multiple causes.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval pressure switch datasheet

Brand
Saunier Duval
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Actual manufacturer
Azbil Corporation (trademark Honeywell), Made in China
Component code
C6065FH1383:2
Contact electric charge
1.5(0.5)A / 250V~
Contact diagram
NC/NO/C
Set pressure
P=0.72 mbar
Maximum allowable pressure
max. 6 mbar
Date/lot code
1612F
CE code / notified body
CE-0063AP3085/1
Internal microswitch (reference)
V-561OR-Q4:1
Internal microswitch (load)
1.5A~ 300VAC
Frequently Asked Questions

Frequently asked questions about the pressure switch

Is this Honeywell C6065FH1383:2 pressure switch suitable for the Saunier Duval STY 300?
Yes, it is the indicated part for the Saunier Duval STY 300 according to our data.
Who manufactures the pressure switch C6065FH1383:2 for the Saunier Duval STY 300?
Manufactured by Azbil Corporation, made in China; Honeywell is the brand under which it is sold.
What fault does this pressure switch cause in the Saunier Duval STY 300 when it fails?
It causes the boiler to lock out by not correctly switching the electrical contact according to the detected pressure.
At what pressure does the pressure switch of the Saunier Duval STY 300 switch?
It has a set point of 0.72 mbar and a maximum allowable switching of 6 mbar, according to the label.

Spare parts related to Saunier Duval Saunier

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model