Huba Control Air Pressure Switch 401.99002 - Beretta Exclusive Mix 26
RefurbishedBerettaPressure switchesHuba Control

Huba Control Air Pressure Switch 401.99002 - Beretta Exclusive Mix 26

Stock · 1 unit

Huba Control air differential pressure switch, ref. 401.99002, manufactured in Wurenlos (Switzerland). It measures the differential pressure generated by the fan and provides an analog output signal (0.3-4.3V) that the boiler uses to confirm the draft before igniting the burner. It is replaced when the boiler locks out without igniting or shows a pressure switch or fan fault.

VAT included

Compatibility

Beretta boilers compatible with reference R2677

Pressure switch with reference R2677. Six confirmed compatibilities: Exclusive Mix 26 CSI and Exclusive Mix 30 RSI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Exclusive Mix 26 CSIExclusive MixContrasted
Beretta Exclusive Mix 30 RSIExclusive MixContrasted
Beretta Super Exclusive Eco Mix 24 CSISuper Exclusive Eco MixContrasted
Beretta Super Exclusive Eco Mix 28 CSISuper Exclusive Eco MixContrasted
Beretta Super Exclusive Mix 26 CSISuper Exclusive MixContrasted
Beretta Meteo MixMeteo MixContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. R2677 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R2677. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch R2677 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and the display shows a fault related to the pressure switch or the fan.

    Cause: This pressure switch sends a signal proportional to the fan pressure; if that signal is out of range, the control unit understands that there is insufficient draft and blocks the ignition.

    Make sure the fan spins freely and at normal speed before replacing the pressure switch; a weak fan can also generate the same fault signal.

  • 02

    The fan starts and sounds normal, but the boiler locks out without igniting.

    Cause: If the differential pressure switch does not confirm the air pressure within the expected range, the control board does not authorize the opening of the gas valve.

    Check that the pressure intake pipes are properly connected, without leaks or kinks, before replacing the component.

  • 03

    The burner ignites and turns off several times in a row for no apparent reason before stabilizing or locking out.

    Cause: An unstable pressure signal from the pressure switch causes the control board to lose and regain flue confirmation during the ignition cycle.

    Check for any accumulated condensation in the siphon or in the silicone tubes; it is a common cause of erratic signals.

  • 04

    The boiler shows a fan error even though the extractor seems to be working well at first glance.

    Cause: The control board does not measure the fan directly; it relies on the signal sent by the pressure switch. A faulty pressure switch can simulate a fan fault that does not exist.

    Before changing the fan, disconnect the pressure switch and check if the fault code changes.

Fault codes for Beretta that this part resolves.

CodeFaultDiagnosis and solution
30Flue gas outlet or air pressure switch (cycle start; lockout).The air pressure switch (Huba R2677) does not switch when the fan starts due to lack of pressure or internal fault; check contact continuity during start-up and pressure at its ports with a manometer, as well as inspect the tubes to the venturi.
31Flue gas outlet or air pressure switch (in cycle; transient anomaly).During operation, the air pressure switch opens/closes unstably due to insufficient pressure or wear of the pressure switch itself; check with a multimeter for intermittent switching and measure the vacuum while the fan modulates, as well as inspect tubes and fittings.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Beretta R2677 pressure switch datasheet

Catalogue reference
R2677
Brand
Beretta
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Differential pressure range
0...+3 mbar (max. 25 mbar)
Power supply
12VDC (10.4-18VDC)
Output signal
0.3-4.3V, RL>15kOhm
Temperature class
T70
Manufacturer
Huba Control, 5436 Wurenlos, Switzerland
Manufacturer code
401.99002
Batch/production code
08-08
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch R2677

Is this Huba Control 401.99002 pressure switch compatible with the Beretta Exclusive Mix 26?
Yes, it is the main compatibility model, along with other models from the Exclusive Mix and Super Exclusive Eco Mix range.
What boiler models are compatible with the Huba Control 401.99002 pressure switch?
It is compatible with the following models: Exclusive Mix 26 CSI, Exclusive Mix 30 RSI, Super Exclusive Eco Mix 24 CSI, Super Exclusive Eco Mix 28 CSI, Super Exclusive Mix 26 CSI, and Meteo Mix.
What code should I request for the pressure switch of the Beretta Exclusive Mix 30?
You must request model 401.99002, which is the one printed on the part.
What faults can be resolved by replacing this pressure switch in a Beretta Super Exclusive Mix?
Replacing the pressure switch can resolve issues such as the boiler locking without igniting or faults with the pressure switch or fan, as the component confirms the draft through an analog signal of 0.3-4.3V before ignition.
How many models are compatible with the Huba Control 401.99002 pressure switch?
There are a total of 6 confirmed models that are compatible.
What fault codes are documented for this pressure switch?
The documented fault codes are 30 and 31.

Spare parts related to Beretta Exclusive Mix

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Huba Control Air Pressure Switch 401.99002 - Beretta Exclusive Mix 26